Sinumerik Alarms

Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D

Sinumerik Alarm 311710 Axis %1 drive %2 resolution SSI motor measuring system invalid

Sinumerik Alarm 311710 Axis %1 drive %2 resolution SSI motor measuring system invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The configuration of the motor measuring…

Sinumerik Alarm 310760 Axis %1 drive %2 bandwidth denominator greater than double natural frequency

Sinumerik Alarm 310760 Axis %1 drive %2 bandwidth denominator greater than double natural frequency Parameters: %1 = NC axis number %2 = Drive number Definitions: The bandwidth denominator of a…

Sinumerik Alarm 310761 Axis %1 drive %2 proportional gain of force controller too high

Sinumerik Alarm 310761 Axis %1 drive %2 proportional gain of force controller too high Parameters: %1 = NC axis number %2 = Drive number Definitions: The P gain of the…

Sinumerik Alarm 310762 Axis %1 drive %2 integral gain for force controller invalid

Sinumerik Alarm 310762 Axis %1 drive %2 integral gain for force controller invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The integral gain in MD 5244:…

Sinumerik Alarm 310753 Axis %1 drive %2 D component for speed controller invalid

Sinumerik Alarm 310753 Axis %1 drive %2 D component for speed controller invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The D component of the speed…

Sinumerik Alarm 380072 Profibus DP: output slot for base address %1 (size %2) not allowed

Sinumerik Alarm 380072 Profibus DP: output slot for base address %1 (size %2) not allowed Parameters: %1 = Logical base address of the requested area %2 = Size of the…

Sinumerik Alarm 380075 Profibus DP: DP I/O failure slave %1

Sinumerik Alarm 380075 Profibus DP: DP I/O failure slave %1 Parameters: %1 = Slave address Definitions: Failure of a PROFIBUS slot used by the NCK for digital or analog I/O….

Sinumerik Alarm 311716 Axis %1 drive %2 SSI measuring system without incremental signals not possible

Sinumerik Alarm 311716 Axis %1 drive %2 SSI measuring system without incremental signals not possible Parameters: %1 = NC axis number %2 = Drive number Definitions: With the present module,…

Sinumerik Alarm 380050 Profibus-DP: multiple assignment of inputs on address %1

Sinumerik Alarm 380050 Profibus-DP: multiple assignment of inputs on address %1 Parameters: %1 = Logical address Definitions: Multiple assignments of input data have been detected in the logical address space….

Sinumerik Alarm 380051 Profibus-DP: multiple assignment of outputs on address %1

Sinumerik Alarm 380051 Profibus-DP: multiple assignment of outputs on address %1 Parameters: %1 = Logical address Definitions: Multiple assignments of input data have been detected in the logical address space….

Sinumerik Alarm 310774 Axis %1 drive %2 zero area and knee area of valve characteristic overlap

Sinumerik Alarm 310774 Axis %1 drive %2 zero area and knee area of valve characteristic overlap Parameters: %1 = NC axis number %2 = Drive number Definitions: The zero area…

Sinumerik Alarm 380060 Profibus-DP: alarm %1 on logical address %2 from unassigned station

Sinumerik Alarm 380060 Profibus-DP: alarm %1 on logical address %2 from unassigned station Parameters: %1 = Alarm class %2 = Logical address Definitions: SDB1000 contains a slave which is not…

Sinumerik Alarm 380070 Profibus DP: no input slot available for base address %1 (length %2)

Sinumerik Alarm 380070 Profibus DP: no input slot available for base address %1 (length %2) Parameters: %1 = Logical base address of the requested area %2 = Size of the…

Sinumerik Alarm 380071 Profibus DP: no output slot available for base address %1 (size %2)

Sinumerik Alarm 380071 Profibus DP: no output slot available for base address %1 (size %2) Parameters: %1 = Logical base address of the requested area %2 = Size of the…

Sinumerik Alarm 311711 Axis %1 drive %2 transmission length SSI motor measuring system invalid

Sinumerik Alarm 311711 Axis %1 drive %2 transmission length SSI motor measuring system invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The configuration of the motor…

Sinumerik Alarm 311712 Axis %1 drive %2 multiturn SSI motor measuring system invalid

Sinumerik Alarm 311712 Axis %1 drive %2 multiturn SSI motor measuring system invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The configuration of a linear SSI…

Sinumerik Alarm 380500 Profibus-DP: fault on drive %1, code %2, value %3, time %4

Sinumerik Alarm 380500 Profibus-DP: fault on drive %1, code %2, value %3, time %4 Parameters: %1 = Axis %2 = Fault code of drive (P824) %3 = Fault value of…

Sinumerik Alarm 311717 Axis %1 drive %2 SSI transmission timeout

Sinumerik Alarm 311717 Axis %1 drive %2 SSI transmission timeout Parameters: %1 = NC axis number %2 = Drive number Definitions: SSI transmission must be able to finish within one…

Sinumerik Alarm 380001 Profibus-DP: startup error, reason %1 parameter %2 %3 %4.

Sinumerik Alarm 380001 Profibus-DP: startup error, reason %1 parameter %2 %3 %4. Parameters: %1 = Cause of the error %2 = Parameter 1 %3 = Parameter 2 %4 = Parameter…

Sinumerik Alarm 380003 Profibus-DP: operating error, reason %1,parameter %2 %3 %4.

Sinumerik Alarm 380003 Profibus-DP: operating error, reason %1,parameter %2 %3 %4. Parameters: %1 = Cause of the error %2 = Parameter 1 %3 = Parameter 2 %4 = Parameter 3…

Sinumerik Alarm 380005 Profibus-DP: bus access conflict, type %1, counter %2

Sinumerik Alarm 380005 Profibus-DP: bus access conflict, type %1, counter %2 Parameters: %1 = Conflict type %2 = Serial number within a conflict sequence Definitions: An access conflict occurred on…

Sinumerik Alarm 380020 Profibus-DP: SDB1000 error %1 for SDB source %2

Sinumerik Alarm 380020 Profibus-DP: SDB1000 error %1 for SDB source %2 Parameters: %1 = Cause of the error %2 = SDB1000 source Definitions: Error in SDB1000 for PROFIBUS DP configuration….

Sinumerik Alarm 380021 Profibus-DP: default SDB1000 was loaded

Sinumerik Alarm 380021 Profibus-DP: default SDB1000 was loaded Definitions: No user-specific SDB1000 exists. The default SDB1000 was loaded during startup. With- out process peripherals, the NC is ready for a…

Sinumerik Alarm 380022 Profibus-DP: configuration of DP master has been changed

Sinumerik Alarm 380022 Profibus-DP: configuration of DP master has been changed Definitions: The PROFIBUS configuration on the DP master was changed during operation, e.g. by downloading a new hardware configuration…

Sinumerik Alarm 380040 Profibus-DP: configuration error %1, parameter %2

Sinumerik Alarm 380040 Profibus-DP: configuration error %1, parameter %2 Parameters: %1 = Cause of the error %2 = Parameter Definitions: The PROFIBUS DP was not generated in SDB1000 in accordance…

Sinumerik Alarm 105064 Error when reading the file!

Sinumerik Alarm 105064 Error when reading the file! Definitions: The specified file could not be read. System-internal error that does not occur in normal operation. Reactions: – – Remedy: –…

Sinumerik Alarm 105051 Output of dynamic long texts for cycle parameterization

Sinumerik Alarm 105051 Output of dynamic long texts for cycle parameterization Definitions: The dynamic long texts for the cycle parameterization are output here. Reactions: – – Remedy: – Program Continuation:…

Sinumerik Alarm 105052 Error in the cycle description of the !

Sinumerik Alarm 105052 Error in the cycle description of the ! Definitions: The cycle description sc.com, uc.com contains a line that cannot be interpreted. This line is output via ….

Sinumerik Alarm 105053 No cycle available in current line!

Sinumerik Alarm 105053 No cycle available in current line! Definitions: The editor’s cursor is in a line that does not contain a cycle. A recompilation is not possible. Reactions: –…

Sinumerik Alarm 105054 Error during cycle description call!

Sinumerik Alarm 105054 Error during cycle description call! Definitions: One of the sc.com, cov.com cycle description files contains a non-interpretable parameter. IInitilization of the cycles is aborted. Reactions: – –…

Sinumerik Alarm 105060 Please wait: Initilization of the cycle support

Sinumerik Alarm 105060 Please wait: Initilization of the cycle support Definitions: The cycle description files are interpreted and prepared for display on the screen. Reactions: – – Remedy: – Program…

Sinumerik Alarm 105061 Error when opening the file!

Sinumerik Alarm 105061 Error when opening the file! Definitions: The specified file could not be opened. System-internal error that does not occur in normal operation. Reactions: – – Remedy: –…

Sinumerik Alarm 105063 Error when positioning in the file %1!

Sinumerik Alarm 105063 Error when positioning in the file %1! Parameters: %1 = File name Definitions: No positioning could be done in the specified file. System-internal error that does not…

Sinumerik Alarm 105075 Not enough axes in the current channel? > Contour with default axis names: X, Z !

Sinumerik Alarm 105075 Not enough axes in the current channel? > Contour with default axis names: X, Z ! Definitions: The default axis names for the required axes are used….

Sinumerik Alarm 109001 No switchover: Switchover disable set in current PLC

Sinumerik Alarm 109001 No switchover: Switchover disable set in current PLC Definitions: MMC would like to go offline from this NCU. The MMC switchover is disabled in the MMC PLC…