Sinumerik Alarm 311712 Axis %1 drive %2 multiturn SSI motor measuring system invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The configuration of a linear SSI motor measuring system is incorrect: A linear measuring system cannot have any multiturn information.
Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.
Remedy:
Set MD_5021 $MD_ENC_ABS_TURN_MOTOR (number of representable revolutions) to 0.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens