Sinumerik Alarm 380022 Profibus-DP: configuration of DP master has been changed
Definitions:
The PROFIBUS configuration on the DP master was changed during operation, e.g. by downloading a new hardware configuration via Step7. Since it is possible that the cycle data have changed, operation cannot be continued and a warm start is required. If the DP master functionality is within the PLC (as on the 840Di), the PLC will have been stopped for the download and alarm 2000 (PLC sign-of-life) output.
Reactions:
– Alarm display.
– Interface signals are set.
– Channel not ready.
– NC Start disable in this channel.
Remedy:
NCK restart If the error cannot be eliminated by this procedure, please make a note of the error text and contact the control system manufacturer.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens