Sinumerik Alarms

Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D

Sinumerik Alarm 300914 Axis %1 drive %2 safe velocity exceeded

Sinumerik Alarm 300914 Axis %1 drive %2 safe velocity exceeded Parameters: %1 = Axis number %2 = Drive number Definitions: The drive is disabled by the reaction configured in MD…

Sinumerik Alarm 300950 Axis %1 drive %2 is not safely referenced

Sinumerik Alarm 300950 Axis %1 drive %2 is not safely referenced Parameters: %1 = Axis number %2 = Drive number Definitions: No stop reaction is initiated. The message will be…

Sinumerik Alarm 300951 Axis %1 drive %2 test stop is running

Sinumerik Alarm 300951 Axis %1 drive %2 test stop is running Parameters: %1 = Axis number %2 = Drive number Definitions: The pulses are deleted. 1. If the positive acknowledgement…

Sinumerik Alarm 300952 Axis %1 drive %2 acceptance test mode is active

Sinumerik Alarm 300952 Axis %1 drive %2 acceptance test mode is active Parameters: %1 = Axis number %2 = Drive number Definitions: The acceptance test mode has been activated by…

Sinumerik Alarm 301701 Axis %1 drive %2 limit value for safe velocity too large

Sinumerik Alarm 301701 Axis %1 drive %2 limit value for safe velocity too large Parameters: %1 = Axis number %2 = Drive number Definitions: Booting has been interrupted. The pulses…

Sinumerik Alarm 301702 Axis %1 drive %2 track inversion incorrect

Sinumerik Alarm 301702 Axis %1 drive %2 track inversion incorrect Parameters: %1 = NC axis number %2 = Drive number Definitions: With rotary spindles without EnDat interface operating with enhanced…

Sinumerik Alarm 300789 Axis %1 drive %2 function not supported on this 611D controller module

Sinumerik Alarm 300789 Axis %1 drive %2 function not supported on this 611D controller module Parameters: %1 = NC axis number %2 = Drive number Definitions: A function was selected…

Sinumerik Alarm 300908 Axis %1 drive %2 stop C triggered

Sinumerik Alarm 300908 Axis %1 drive %2 stop C triggered Parameters: %1 = Axis number %2 = Drive number Definitions: The drive is disabled via STOP C. At the end…

Sinumerik Alarm 300910 Axis %1 drive %2 stop E triggered

Sinumerik Alarm 300910 Axis %1 drive %2 stop E triggered Parameters: %1 = Axis number %2 = Drive number Definitions: The drive ws stopped by the NC with STOP E….

Sinumerik Alarm 300864 Axis %1 drive %2 emergency retraction mode/generator mode not possible

Sinumerik Alarm 300864 Axis %1 drive %2 emergency retraction mode/generator mode not possible Parameters: %1 = NC axis number %2 = Drive number Definitions: Emergency retraction/Generator operation is only possible…

Sinumerik Alarm 300865 Axis %1 drive %2 measurement of DC link voltage not possible

Sinumerik Alarm 300865 Axis %1 drive %2 measurement of DC link voltage not possible Parameters: %1 = NC axis number %2 = Drive number Definitions: If the fixed voltage MD…

Sinumerik Alarm 300875 Axis %1 drive %2 fixed link voltage of axes differ

Sinumerik Alarm 300875 Axis %1 drive %2 fixed link voltage of axes differ Parameters: %1 = NC axis number %2 = Drive number Definitions: An unequal fixed voltage MD1161: $MD_FIXED_LINK_VOLTAGE…

Sinumerik Alarm 300888 Axis %1 drive %2 parameterization error in current control adaption

Sinumerik Alarm 300888 Axis %1 drive %2 parameterization error in current control adaption Parameters: %1 = NC axis number %2 = Drive number Definitions: The upper current limit in MD…

Sinumerik Alarm 300900 Axis %1 drive %2 stop A triggered

Sinumerik Alarm 300900 Axis %1 drive %2 stop A triggered Parameters: %1 = Axis number %2 = Drive number Definitions: The drive is disabled via STOP A. This blocks the…

Sinumerik Alarm 300901 Axis %1 drive %2 stop B triggered

Sinumerik Alarm 300901 Axis %1 drive %2 stop B triggered Parameters: %1 = Axis number %2 = Drive number Definitions: The drive is disabled via STOP B. This blocks the…

Sinumerik Alarm 300909 Axis %1 drive %2 stop D triggered

Sinumerik Alarm 300909 Axis %1 drive %2 stop D triggered Parameters: %1 = Axis number %2 = Drive number Definitions: The drive ws stopped by the NC with STOP D….

Sinumerik Alarm 300911 Axis %1 drive %2 error in one monitoring channel

Sinumerik Alarm 300911 Axis %1 drive %2 error in one monitoring channel Parameters: %1 = NC axis number %2 = Drive number Definitions: The mutual comparison of the two monitoring…

Sinumerik Alarm 300906 Axis %1 drive %2 safe braking ramp exceeded

Sinumerik Alarm 300906 Axis %1 drive %2 safe braking ramp exceeded Parameters: %1 = NC axis number %2 = Drive number Definitions: The drive is disabled via STOP A. Request:…

Sinumerik Alarm 300907 Axis %1 drive %2 tolerance for safe operational stop exceeded

Sinumerik Alarm 300907 Axis %1 drive %2 tolerance for safe operational stop exceeded Parameters: %1 = Axis number %2 = Drive number Definitions: The drive is disabled via STOP A…

Sinumerik Alarm 300915 Axis %1 drive %2 safe end positions exceeded

Sinumerik Alarm 300915 Axis %1 drive %2 safe end positions exceeded Parameters: %1 = Axis number %2 = Drive number Definitions: The drive is disabled by the reaction configured in…

Sinumerik Alarm 301703 Axis %1 drive %2 encoder/motor type are not compatible

Sinumerik Alarm 301703 Axis %1 drive %2 encoder/motor type are not compatible Parameters: %1 = NC axis number %2 = Drive number Definitions: If a linear motor was selected (motor…

Sinumerik Alarm 301706 Axis %1 drive %2 parameterization of cam position invalid

Sinumerik Alarm 301706 Axis %1 drive %2 parameterization of cam position invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: At least one of the parameterized cams…

Sinumerik Alarm 301707 Axis %1 drive %2 parameterization of modulo value for safe cam (SN) invalid

Sinumerik Alarm 301707 Axis %1 drive %2 parameterization of modulo value for safe cam (SN) invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The cam modulo…

Sinumerik Alarm 301708 Axis %1 drive %2 actual value synchronization not allowed

Sinumerik Alarm 301708 Axis %1 drive %2 actual value synchronization not allowed Parameters: %1 = NC axis number %2 = Drive number Definitions: The actual value synchronization for drift/slippage in…

Sinumerik Alarm 301709 Axis %1 drive %2 submodule with integrated linearization invalid

Sinumerik Alarm 301709 Axis %1 drive %2 submodule with integrated linearization invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: If a submodule with integrated linearization is…

Sinumerik Alarm 301710 Axis %1 drive %2 resolution SSI motor measuring system invalid

Sinumerik Alarm 301710 Axis %1 drive %2 resolution SSI motor measuring system invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The configuration of the motor measuring…

Sinumerik Alarm 301711 Axis %1 drive %2 transmission length SSI motor measuring system invalid

Sinumerik Alarm 301711 Axis %1 drive %2 transmission length SSI motor measuring system invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The configuration of the motor…

Sinumerik Alarm 301712 Axis %1 drive %2 multiturn SSI motor measuring system invalid

Sinumerik Alarm 301712 Axis %1 drive %2 multiturn SSI motor measuring system invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The configuration of a linear SSI…

Sinumerik Alarm 301713 Axis %1 drive %2 resolution SSI direct measuring system invalid

Sinumerik Alarm 301713 Axis %1 drive %2 resolution SSI direct measuring system invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Configuration of the direct measuring system…

Sinumerik Alarm 301714 Axis %1 drive %2 transmission length SSI direct measuring system invalid

Sinumerik Alarm 301714 Axis %1 drive %2 transmission length SSI direct measuring system invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Configuration of the direct measuring…

Sinumerik Alarm 301719 Axis %1 drive %2 power section data incomplete

Sinumerik Alarm 301719 Axis %1 drive %2 power section data incomplete Parameters: %1 = NC axis number %2 = Drive number Definitions: The data for the power section are incomplete:…

Sinumerik Alarm 301704 Axis %1 drive %2 pole pair width/division of linear scale (internal) out of range

Sinumerik Alarm 301704 Axis %1 drive %2 pole pair width/division of linear scale (internal) out of range Parameters: %1 = NC axis number %2 = Drive number Definitions: With linear…

Sinumerik Alarm 301705 Axis %1 drive %2 distance-coded scale incorrectly parameterized

Sinumerik Alarm 301705 Axis %1 drive %2 distance-coded scale incorrectly parameterized Parameters: %1 = NC axis number %2 = Drive number Definitions: When selecting a distance-coded scale (MD_1011.7=1) it is…

Sinumerik Alarm 310705 Axis %1 drive %2 monitoring cycle times of axes differ

Sinumerik Alarm 310705 Axis %1 drive %2 monitoring cycle times of axes differ Parameters: %1 = NC axis number %2 = Drive number Definitions: The monitoring cycle MD 5002: MONITOR_CYCLE_TIME…

Sinumerik Alarm 301717 Axis %1 drive %2 SSI transmission timeout

Sinumerik Alarm 301717 Axis %1 drive %2 SSI transmission timeout Parameters: %1 = NC axis number %2 = Drive number Definitions: The SSI transmission must be completed within an NC…