Selca G60 G61 Scaling factor
G60 Cancels G61
G60 Cancels G61 (scaling factor)
Programming
G60
G61 Scaling factor
G61 Scaling factor
Programming
G61 K...
G61 [X...] [Y...] [Z...] [F...] [Q...] [J...]
Parameters
| Parameter | Description |
|---|---|
| K | scaling factor (multiplier) to be applied to all axes. |
| X,Y,Z | scaling factor to be applied to each axis. |
| F | scaling factor to be applied to the feed rate. |
| Q | scale factor to apply to the feed speed of axis movements perpendicular to the working plane ( for G17, for G18, for G19). |
| J | scale factor to apply to the rapid speed. |
Enabled: until a G60 is programmed.
G61 Programmable zone scaling
G61 Programmable zone scaling
Programming
G61 [X...] [Y...] [Z...] D0=... D1=... D2=... D3=... D4=... [D5=...] [D6=...] [D7=...] [D8=...] [D9=...] [D10=...]

Parameters
| Parameter | Description |
|---|---|
| X | scaling factor for X-axis first zone. |
| Y | scaling factor for Y-axis first zone. |
| Z | scaling factor for Z-axis first zone. |
| D0 | selection of the axis along which the 3 zones are defined: D0=1 X-axis. D0=2 Y-axis. D0=3 Z-axis. |
| D1= | end coordinate of the first zone. |
| D2= | starting coordinate of the second zone (>D1). |
| D3= | end coordinate of the second zone (>D2). |
| D4= | starting coordinate of the third zone (>D3). |
| D5= | scaling factor for X-axis second zone. |
| D6= | scaling factor for Y-axis second zone. |
| D7= | scaling factor for Z-axis second zone. |
| D8= | scaling factor for X-axis third zone. |
| D9= | scaling factor for Y-axis third zone. |
| D10= | scaling factor for Z-axis third zone. |
Enabled: until a G60 is programmed.