Sinumerik Alarms

Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D

Sinumerik Alarm 300502 Axis %1 drive %2 maximum current monitoring of phase current R

Sinumerik Alarm 300502 Axis %1 drive %2 maximum current monitoring of phase current R Parameters: %1 = NC axis number %2 = Drive number Definitions: The phase current R is…

Sinumerik Alarm 300202 Axis %1 drive %2 CRC error, error location %3

Sinumerik Alarm 300202 Axis %1 drive %2 CRC error, error location %3 Parameters: %1 = NC axis number %2 = Drive number %3 = Error location Definitions: The cross-check (CRC)…

Sinumerik Alarm 300401 Drive software for type %1, block %2 missing or incorrect

Sinumerik Alarm 300401 Drive software for type %1, block %2 missing or incorrect Parameters: %1 = Drive type %2 = Block number Definitions: Either there is no software for this…

Sinumerik Alarm 300403 Axis %1 drive %2 drive software and drive MD with different version numbers

Sinumerik Alarm 300403 Axis %1 drive %2 drive software and drive MD with different version numbers Parameters: %1 = NC axis number %2 = Drive number Definitions: The version number…

Sinumerik Alarm 300515 Axis %1 drive %2 power section heat sink temperature exceeded

Sinumerik Alarm 300515 Axis %1 drive %2 power section heat sink temperature exceeded Parameters: %1 = NC axis number %2 = Drive number Definitions: The temperature of the power section…

Sinumerik Alarm 300511 Axis %1 drive %2 measuring function active

Sinumerik Alarm Parameters: %1 = NC axis number %2 = Drive number Definitions: The measuring function (e.g. frequency response measurement was active during the switching on operation (power supply start-up…

Sinumerik Alarm 300704 Axis %1 drive %2 speed controller cycle time invalid

Sinumerik Alarm 300704 Axis %1 drive %2 speed controller cycle time invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: An illegal value has been entered in…

Sinumerik Alarm 300705 Axis %1 drive %2 position controller cycle time invalid

Sinumerik Alarm 300705 Axis %1 drive %2 position controller cycle time invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The monitor in the 611D module has…

Sinumerik Alarm 300706 Axis %1 drive %2 monitoring cycle time invalid

Sinumerik Alarm 300706 Axis %1 drive %2 monitoring cycle time invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Monitoring cycle MD 1002: $MD_MONITOR_CYCLE_TIME is invalid. Reactions:…

Sinumerik Alarm 300501 Axis %1 drive %2 maximum current monitoring

Sinumerik Alarm 300501 Axis %1 drive %2 maximum current monitoring Parameters: %1 = NC axis number %2 = Drive number Definitions: 1. A serious fault occured during actual current measurement….

Sinumerik Alarm 300503 Axis %1 drive %2 maximum current monitoring of phase current S

Sinumerik Alarm 300503 Axis %1 drive %2 maximum current monitoring of phase current S Parameters: %1 = NC axis number %2 = Drive number Definitions: The phase current S is…

Sinumerik Alarm 300504 Axis %1 drive %2 measuring circuit error of motor measuring system

Sinumerik Alarm 300504 Axis %1 drive %2 measuring circuit error of motor measuring system Parameters: %1 = NC axis number %2 = Drive number Definitions: Signal level of the motor…

Sinumerik Alarm 300505 Axis %1 drive %2 measuring circuit error of absolute track, code %3

Sinumerik Alarm 300505 Axis %1 drive %2 measuring circuit error of absolute track, code %3 Parameters: %1 = NC axis number %2 = Drive number %3 = Fine error coding…

Sinumerik Alarm 300506 Axis %1 drive %2 NC sign-of-life failure

Sinumerik Alarm 300506 Axis %1 drive %2 NC sign-of-life failure Parameters: %1 = NC axis number %2 = Drive number Definitions: Upon servo enable, the NC must update the sign-of-life…

Sinumerik Alarm 300507 Axis %1 drive %2 synchronization error of rotor position

Sinumerik Alarm 300507 Axis %1 drive %2 synchronization error of rotor position Parameters: %1 = NC axis number %2 = Drive number Definitions: There is a difference of more than…

Sinumerik Alarm 300508 Axis %1 drive %2 zero mark monitoring of motor measuring system

Sinumerik Alarm 300508 Axis %1 drive %2 zero mark monitoring of motor measuring system Parameters: %1 = NC axis number %2 = Drive number Definitions: An error was detected in…

Sinumerik Alarm 300509 Axis %1 drive %2 current frequency exceeded

Sinumerik Alarm 300509 Axis %1 drive %2 current frequency exceeded Parameters: %1 = NC axis number %2 = Drive number Definitions: The motor has exceeded the maximum current frequency fmax…

Sinumerik Alarm 300702 Axis %1 drive %2 base cycle time invalid

Sinumerik Alarm 300702 Axis %1 drive %2 base cycle time invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The base cycle time set on the NC…

Sinumerik Alarm 300510 Axis %1 drive %2 error on actual current measurement zero balancing

Sinumerik Alarm 300510 Axis %1 drive %2 error on actual current measurement zero balancing Parameters: %1 = NC axis number %2 = Drive number Definitions: The value of the actual…

Sinumerik Alarm 300703 Axis %1 drive %2 current cycle time invalid

Sinumerik Alarm 300703 Axis %1 drive %2 current cycle time invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: An illegal value has been entered in the…

Sinumerik Alarm 300721 Axis %1 drive %2 zero-load current greater than rated motor current

Sinumerik Alarm 300721 Axis %1 drive %2 zero-load current greater than rated motor current Parameters: %1 = NC axis number %2 = Drive number Definitions: The no-load current of the…

Sinumerik Alarm 300722 Axis %1 drive %2 zero-load motor current greater than rated current of power section

Sinumerik Alarm 300722 Axis %1 drive %2 zero-load motor current greater than rated current of power section Parameters: %1 = NC axis number %2 = Drive number Definitions: On the…

Sinumerik Alarm 300707 Axis %1 drive %2 basic cycle times of axes differ

Sinumerik Alarm 300707 Axis %1 drive %2 basic cycle times of axes differ Parameters: %1 = NC axis number %2 = Drive number Definitions: In a 2-axis module, the basic…

Sinumerik Alarm 300723 Axis %1 drive %2 STS configuration of axes differ

Sinumerik Alarm 300723 Axis %1 drive %2 STS configuration of axes differ Parameters: %1 = NC axis number %2 = Drive number Definitions: The configuration of the control block MD…

Sinumerik Alarm 300606 Axis %1 drive %2 flux controller at limit

Sinumerik Alarm 300606 Axis %1 drive %2 flux controller at limit Parameters: %1 = NC axis number %2 = Drive number Definitions: The specified flux setpoint cannot be achieved even…

Sinumerik Alarm 300724 Axis %1 drive %2 number of pole pairs invalid

Sinumerik Alarm 300724 Axis %1 drive %2 number of pole pairs invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: FDD: The configured number of pole pairs…

Sinumerik Alarm 300607 Axis %1 drive %2 current controller at limit

Sinumerik Alarm 300607 Axis %1 drive %2 current controller at limit Parameters: %1 = NC axis number %2 = Drive number Definitions: The specified current setpoint cannot be injected into…

Sinumerik Alarm 300608 Axis %1 drive %2 speed controller at limit

Sinumerik Alarm 300608 Axis %1 drive %2 speed controller at limit Parameters: %1 = NC axis number %2 = Drive number Definitions: The speed controller output is lying for an…

Sinumerik Alarm 300609 Axis %1 drive %2 encoder cut-off frequency exceeded

Sinumerik Alarm 300609 Axis %1 drive %2 encoder cut-off frequency exceeded Parameters: %1 = NC axis number %2 = Drive number Definitions: Actual speed value exceeds encoder limit frequency fg,max…

Sinumerik Alarm 300727 Axis %1 drive %2 reactance less than or equal to zero

Sinumerik Alarm 300727 Axis %1 drive %2 reactance less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD 1139:…

Sinumerik Alarm 300610 Axis %1 drive %2 rotor position identification failed

Sinumerik Alarm 300610 Axis %1 drive %2 rotor position identification failed Parameters: %1 = NC axis number %2 = Drive number Definitions: The rotor position could not be determined from…

Sinumerik Alarm 300611 Axis %1 drive %2 generator mode: Motion at rotor position identification

Sinumerik Alarm 300611 Axis %1 drive %2 generator mode: Motion at rotor position identification Parameters: %1 = NC axis number %2 = Drive number Definitions: During the measurement, the motor…

Sinumerik Alarm 300612 Axis %1 drive %2 illegal current during rotor position identification

Sinumerik Alarm 300612 Axis %1 drive %2 illegal current during rotor position identification Parameters: %1 = NC axis number %2 = Drive number Definitions: 1. With rotor position identification active,…

Sinumerik Alarm 300730 Axis %1 drive %2 rotor resistance invalid

Sinumerik Alarm 300730 Axis %1 drive %2 rotor resistance invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in drive MD 1138: $MD_ROTOR_COLD_RESISTANCE (cold rotor…

Sinumerik Alarm 300613 Axis %1 drive %2 maximum permissible motor temperature exceeded

Sinumerik Alarm 300613 Axis %1 drive %2 maximum permissible motor temperature exceeded Parameters: %1 = NC axis number %2 = Drive number Definitions: The motor temperature (measured via the temperature…