Haas Alarm: 423 X SCALE/SCREW MISMATCH – Haas Mill

Alarm: 423 X SCALE/SCREW MISMATCH – Haas Mill Haas Alarm Description: Scale-induced correction exceeds one motor revolution.

Haas Alarm: 423 SERVO BAR EOB SWITCH POSITION UNKNOWN – Haas Lathe

Alarm: 423 SERVO BAR EOB SWITCH POSITION UNKNOWN – Haas Lathe Haas Alarm Description: Place 12 inch standard bar in charging position and run G105 Q5 to set End of…

Haas Alarm: 422 POCKET TABLE ERROR – Haas Mill

Alarm: 422 POCKET TABLE ERROR – Haas Mill Haas Alarm Description: If the machine has a 50 taper spindle, there must be 2 dashes between L’s. L’s must be surrounded…

Haas Alarm: 421 NO VALID POCKETS – Haas Mill

Alarm: 421 NO VALID POCKETS – Haas Mill Haas Alarm Description: Pocket Table is full of dashes.

Haas Alarm: 420 PROGRAM NUMBER MISMATCH

Alarm: 420 PROGRAM NUMBER MISMATCH Haas Alarm Description: O code in program being loaded to machine memory did not match O code entered at the keyboard to receive. This is…

Haas Alarm: 419 INVALID FUNCTION FOR DNC

Alarm: 419 INVALID FUNCTION FOR DNC Haas Alarm Description: A code found on input of a DNC program could not be interpreted.

Haas Alarm: 418 RS-232 BREAK

Alarm: 418 RS-232 BREAK Haas Alarm Description: Break condition while receiving. The sending device set the line to a break condition.This might also be caused by a simple break in…

Haas Alarm: 417 RS-232 FRAMING ERROR

Alarm: 417 RS-232 FRAMING ERROR Haas Alarm Description: Data received was garbled and proper framing bits were not found. One or more characters of the data will be lost. Check…

Haas Alarm: 416 RS-232 PARITY ERROR

Alarm: 416 RS-232 PARITY ERROR Haas Alarm Description: Data received by CNC has bad parity. Check parity settings, number of data bits and speed. Check your cable configuration, cable needs…

Haas Alarm: 415 RS-232 OVERRUN

Alarm: 415 RS-232 OVERRUN Haas Alarm Description: Data sent too fast to CNC. Data sent too fast to CNC, try slower baud rate.

Haas Alarm: 414 RS-232 BUFFER OVERFLOW

Alarm: 414 RS-232 BUFFER OVERFLOW Haas Alarm Description: Computer sending data may not be responding to XOFF. Data sent too fast to CNC, try slower baud rate and check PC…

Haas Alarm: 413 RS-232 LOAD INSUFFICIENT MEMORY

Alarm: 413 RS-232 LOAD INSUFFICIENT MEMORY Haas Alarm Description: Program received does not fit into available free memory.Check the space available in the LIST PROG and possibly delete some programs…

Haas Alarm: 412 RS-232 UNEXPECTED END OF INPUT

Alarm: 412 RS-232 UNEXPECTED END OF INPUT Haas Alarm Description: Program should begin and end with % sign. No text should follow the second % sign. Check your file.

Haas Alarm: 411 RS-232 EMPTY PROG

Alarm: 411 RS-232 EMPTY PROG Haas Alarm Description: No program number found between % signs in file. Check file for formatting.

Haas Alarm: 410 FILE INVALID V CODE – Haas Mill

Alarm: 410 FILE INVALID V CODE – Haas Mill Haas Alarm Description: Positive or negative number must exist after the ‘V’ character in the parameter and setting files, and the…

Haas Alarm: 410 RS-232 INVALID V CODE – Haas Lathe

Alarm: 410 RS-232 INVALID V CODE – Haas Lathe Haas Alarm Description: Bad Parameter or Setting data. User was loading settings or parameters and something was wrong with the data.

Haas Alarm: 409 FILE INVALID N CODE – Haas Mill

Alarm: 409 FILE INVALID N CODE – Haas Mill Haas Alarm Description: Positive number must exist after the N character in parameter and setting files, and the block data cannot…

Haas Alarm: 409 RS-232 INVALID N CODE – Haas Lathe

Alarm: 409 RS-232 INVALID N CODE – Haas Lathe Haas Alarm Description: Bad Parameter or Setting data. User was loading settings or parameters and something was wrong with the data.

Haas Alarm: 408 RS-232 NUMBER RANGE ERROR

Alarm: 408 RS-232 NUMBER RANGE ERROR Haas Alarm Description: Check your program. The program will be stored but the bad data is turned into a comment. Check program for comment…

Haas Alarm: 407 RS-232 INVALID CODE

Alarm: 407 RS-232 INVALID CODE Haas Alarm Description: The program will be stored but the bad data is turned into a comment. Check program for comment ( ?) or message…

Haas Alarm: 406 RS-232 MISSING CODE

Alarm: 406 RS-232 MISSING CODE Haas Alarm Description: Bad data was received. The program is stored but the bad data is turned into a comment. Check your program. Check program…

Haas Alarm: 405 RS-232 ILLEGAL PROG NAME

Alarm: 405 RS-232 ILLEGAL PROG NAME Haas Alarm Description: Check files being loaded. Program name must be Onnnn and be at beginning of a block by itself. Program number must…

Haas Alarm: 404 RS-232 NO PROG NAME

Alarm: 404 RS-232 NO PROG NAME Haas Alarm Description: Program number required in file when sending to CNC. Program must have a name beginning with the letter “O”. Check program…

Haas Alarm: 403 TOO MANY PROGS

Alarm: 403 TOO MANY PROGS Haas Alarm Description: Control memory program storage cannot exceed 500 individual program numbers.

Haas Alarm: 402 POSSIBLE CORRUPTED FILE

Alarm: 402 POSSIBLE CORRUPTED FILE Haas Alarm Description: Parameters being loaded do not match expected parameters. This can be due to loading an older or newer parameter file than the…

Haas Alarm: 401 INVALID TANGENT IN GROUP 1 CORNER ROUNDING OR CHAMFERING – Haas Mill

Alarm: 401 INVALID TANGENT IN GROUP 1 CORNER ROUNDING OR CHAMFERING – Haas Mill Haas Alarm Description: The point or angle calculated has yielded invalid results in automatic chamfering or…

Haas Alarm: 401 INVALID TANGENT IN GROUP 1 CORNER ROUNDING – Haas Lathe

Alarm: 401 INVALID TANGENT IN GROUP 1 CORNER ROUNDING – Haas Lathe Haas Alarm Description: Check your geometry.

Haas Alarm: 400 SKIP SIGNAL DURING RESTART

Alarm: 400 SKIP SIGNAL DURING RESTART Haas Alarm Description: A skip signal G-code (G31, G35, G36, G37, G136) was found during program restart. Graphics mode and program restart cannot simulate…

Haas Alarm: 399 INVALID U CODE – Haas Lathe

Alarm: 399 INVALID U CODE – Haas Lathe Haas Alarm Description: In the context that the U code was used it had an invalid value. Was it positive?

Haas Alarm: 398 AUX AXIS SERVO OFF

Alarm: 398 AUX AXIS SERVO OFF Haas Alarm Description: Aux. axis servo shut off due to a fault.

Haas Alarm: 397 AUX AXIS IN G93 BLOCK – Haas Mill

Alarm: 397 AUX AXIS IN G93 BLOCK – Haas Mill Haas Alarm Description: Auxiliary axis interpolation cannot be commanded in G93 feed mode.Check your program. An auxiliary axis cannot be…

Haas Alarm: 397 INVALID D CODE – Haas Lathe

Alarm: 397 INVALID D CODE – Haas Lathe Haas Alarm Description: A D value entered in a Canned Cycle must be a positive value. The D will always refer to…

Haas Alarm: 396 INVALID G107 ROTARY AXIS SPECIFIED – Haas Mill

Alarm: 396 INVALID G107 ROTARY AXIS SPECIFIED – Haas Mill Haas Alarm Description: The rotary axis specified in G107 is not a valid axis,or has been disabled. G107 requires either…

Haas Alarm: 396 CONFLICTING AXES – Haas Lathe

Alarm: 396 CONFLICTING AXES – Haas Lathe Haas Alarm Description: An Incremental and Absolute command cannot be used in the same block of code. For example, X and U cannot…

Haas Alarm: 395 NO G107 ROTARY AXIS SPECIFIED – Haas Mill

Alarm: 395 NO G107 ROTARY AXIS SPECIFIED – Haas Mill Haas Alarm Description: For axis substitution, a rotary axis must be specified in order to perform cylindrical mapping to function….