Haas Alarms

Haas Alarms – Haas Alarm Codes with description.

Haas Alarm: 365 P DEFINITION ERROR

Alarm: 365 P DEFINITION ERROR Haas Alarm Description: P value not defined, or P value out of range. An M59 or M69 must have a P value between the range…

Haas Alarm: 364 NO CIRC INTERP AUX AXIS

Alarm: 364 NO CIRC INTERP AUX AXIS Haas Alarm Description: Only rapid or feed is allowed with aux axes.

Haas Alarm: 363 COOLANT LOCKED OFF

Alarm: 363 COOLANT LOCKED OFF Haas Alarm Description: Setting 32 is set to off when coolant was turned on in programmed M-codes or by keypad.

Haas Alarm: 362 TOOL USAGE ALARM

Alarm: 362 TOOL USAGE ALARM Haas Alarm Description: Tool life limit was reached. To continue, hi-light the usage counter in the current commands tool life display and press Origin. Then…

Haas Alarm: 361 GEAR CHANGER DISABLED

Alarm: 361 GEAR CHANGER DISABLED Haas Alarm Description: Check Parameter 57 in Mills. Not a normal condition for Lathes.

Haas Alarm: 360 TOOL CHANGER DISABLED

Alarm: 360 TOOL CHANGER DISABLED Haas Alarm Description: Check Parameter 57 in Mills. Not a normal condition for Lathes.

Haas Alarm: 359 INVALID I, J OR K IN G12 OR G13 – Haas Mill

Alarm: 359 INVALID I, J OR K IN G12 OR G13 – Haas Mill Haas Alarm Description: Check your program for G12 and G13 formatting of variables.

Haas Alarm: 358 MULTIPLE AUX AXIS

Alarm: 358 MULTIPLE AUX AXIS Haas Alarm Description: Can only move one auxiliary axis at a time.

Haas Alarm: 357 AUX AXIS DISABLED

Alarm: 357 AUX AXIS DISABLED Haas Alarm Description: Aux axes are disabled.

Haas Alarm: 356 AUX AXIS TRAVEL LIMIT

Alarm: 356 AUX AXIS TRAVEL LIMIT Haas Alarm Description: Aux axes are attempting to travel past their limits.

Haas Alarm: 355 AUX AXIS POSITION MISMATCH

Alarm: 355 AUX AXIS POSITION MISMATCH Haas Alarm Description: Mismatch between machine and aux axis position. Check aux axes and interfaces. Make sure no manual inputs occur to aux axes.

Haas Alarm: 354 AUX AXIS DISCONNECTED

Alarm: 354 AUX AXIS DISCONNECTED Haas Alarm Description: Aux axis not responding. Check auxiliary axes and RS-232 connections.

Haas Alarm: 353 AUX AXIS NO HOME – Haas Mill

Alarm: 353 AUX AXIS NO HOME – Haas Mill Haas Alarm Description: A Zero Ret has not been done yet on the aux axes. Check auxiliary axes.

Haas Alarm: 353 AUX AXIS NO HOME – Haas Lathe

Alarm: 353 AUX AXIS NO HOME – Haas Lathe Haas Alarm Description: A Zero Ret has not been done yet on the aux axes. Check auxiliary axes.Status from control was…

Haas Alarm: 352 AUX AXIS POWER OFF

Alarm: 352 AUX AXIS POWER OFF Haas Alarm Description: Aux C, U, V, or W axis indicate servo off. Check auxiliary axes. Status from control was Off.

Haas Alarm: 351 INVALID P CODE

Alarm: 351 INVALID P CODE Haas Alarm Description: In a block with G103, value for P must be between 0 and 15. Check your program.

Haas Alarm: 350 CUTTER COMP LOOK AHEAD ERROR

Alarm: 350 CUTTER COMP LOOK AHEAD ERROR Haas Alarm Description: There are too many non-movement blocks between motions when cutter compensation is being used. Remove intervening blocks.

Haas Alarm: 349 PROG STOP WITHOUT CANCELING CUTTER COMP

Alarm: 349 PROG STOP WITHOUT CANCELING CUTTER COMP Haas Alarm Description: A cutter compensation exit move with G40 is required before a program stop M00, M01, or end of program…

Haas Alarm: 348 MOTION NOT ALLOWED IN G93 MODE – Haas Mill

Alarm: 348 MOTION NOT ALLOWED IN G93 MODE – Haas Mill Haas Alarm Description: This alarm is generated if the mill is in Inverse Time Feed mode, and a G12,…

Haas Alarm: 348 ILLEGAL SPIRAL MOTION – Haas Lathe

Alarm: 348 ILLEGAL SPIRAL MOTION – Haas Lathe Haas Alarm Description: Linear axis path is too long. For helical motions, the linear path must not be more than the length…

Haas Alarm: 346 M CODE DISABLED A – Haas Mill

Alarm: 346 M CODE DISABLED A – Haas Mill Haas Alarm Description: M80 or M81 was commanded. These commands are allowed only for the Auto Door feature with Setting 51…

Haas Alarm: 346 M CODE DISABLED – Haas Lathe

Alarm: 346 M CODE DISABLED – Haas Lathe Haas Alarm Description: M80 or M81 was commanded. These commands are allowed only for the Auto Door feature with Setting 51 Door…

Haas Alarm: 345 INVALID R VALUE IN M19 OR G105 – Haas Lathe

Alarm: 345 INVALID R VALUE IN M19 OR G105 – Haas Lathe Haas Alarm Description: R value must be positive.

Haas Alarm: 344 CUTTER COMP WITH G18 & G19 – Haas Mill

Alarm: 344 CUTTER COMP WITH G18 & G19 – Haas Mill Haas Alarm Description: Cutter compensation G41 or G42 not allowed in planes other than XY plane (G17).

Haas Alarm: 344 CUTTER COMP WITH G17 & G19 – Haas Lathe

Alarm: 344 CUTTER COMP WITH G17 & G19 – Haas Lathe Haas Alarm Description: Cutter compensation G41 or G42 not allowed in planes other than XY plane (G17).

Haas Alarm: 343 DISPLAY QUEUE RECORD FULL

Alarm: 343 DISPLAY QUEUE RECORD FULL Haas Alarm Description: Cycle power on the machine. If the alarm reoccurs, call your dealer and report the sequence of events that led to…

Haas Alarm: 342 CUTTER COMP PATH TOO SMALL

Alarm: 342 CUTTER COMP PATH TOO SMALL Haas Alarm Description: Geometry not possible to apply specified compensation amount.Check your geometry use a smaller tool.

Haas Alarm: 341 CUTTER COMP END WITH G02 OR G03

Alarm: 341 CUTTER COMP END WITH G02 OR G03 Haas Alarm Description: Cutter compensation must end with a linear move. Check program and turn off cutter compensation on in a…

Haas Alarm: 340 CUTTER COMP BEGIN WITH G02 OR G03

Alarm: 340 CUTTER COMP BEGIN WITH G02 OR G03 Haas Alarm Description: Cutter compensation must begin with a linear move.Check program and turn on cutter compensation on in a G01…

Haas Alarm: 339 MULTIPLE CODES

Alarm: 339 MULTIPLE CODES Haas Alarm Description: Only one M, X, Y, Z, A, Q etc. allowed in a block. Only one G code from the same group per block.

Haas Alarm: 338 INVALID IJK AND XYZ IN G02 OR G03

Alarm: 338 INVALID IJK AND XYZ IN G02 OR G03 Haas Alarm Description: Intersection points in G02 and G03 start and end must have an accuracy of 0.0010 inches (0.010…

Haas Alarm: 337 GOTO OR P LINE NOT FOUND

Alarm: 337 GOTO OR P LINE NOT FOUND Haas Alarm Description: Subprogram is not in memory, or P code is incorrect. P Not Found.Check your program.

Haas Alarm: 336 A AXIS DISABLED – Haas Mill

Alarm: 336 A AXIS DISABLED – Haas Mill Haas Alarm Description: Attempt was made to program the A-axis while it was disabled (Disabled bit in Parameter 43 set to 1),…

Haas Alarm: 336 A AXIS DISABLED – Haas Lathe

Alarm: 336 A AXIS DISABLED – Haas Lathe Haas Alarm Description: An attempt was made to program the A-axis while it was disabled (Disabled bit in Parameter 43 set to…

Haas Alarm: 335 Z AXIS DISABLED

Alarm: 335 Z AXIS DISABLED Haas Alarm Description: Parameter has disabled this axis.