Haas Alarms
Haas Alarms – Haas Alarm Codes with description.
Haas Alarm: 334 Y AXIS DISABLED – Haas Mill
Alarm: 334 Y AXIS DISABLED – Haas Mill Haas Alarm Description: Parameter has disabled this axis.
Haas Alarm: 334 Y AXIS DISABLED – Haas Lathe
Alarm: 334 Y AXIS DISABLED – Haas Lathe Haas Alarm Description: Parameter has disabled Live Tooling.
Haas Alarm: 333 X AXIS DISABLED
Alarm: 333 X AXIS DISABLED Haas Alarm Description: Parameter has disabled this axis.
Haas Alarm: 332 H AND T NOT MATCHED – Haas Mill
Alarm: 332 H AND T NOT MATCHED – Haas Mill Haas Alarm Description: This alarm is generated when Setting 15 is turned ON. An H code number in a running…
Haas Alarm: 331 RANGE ERROR
Alarm: 331 RANGE ERROR Haas Alarm Description: Alphabetic number assignment too large. Check your program.
Haas Alarm: 330 UNDEFINED MACRO CALL
Alarm: 330 UNDEFINED MACRO CALL Haas Alarm Description: A macro called a program number not in memory, or a macro variable was accessed by user program but that macro program…
Haas Alarm: 329 UNDEFINED M CODE
Alarm: 329 UNDEFINED M CODE Haas Alarm Description: That M code is not defined and is not a macro call. Check your program.
Haas Alarm: 328 INVALID TOOL NUMBER
Alarm: 328 INVALID TOOL NUMBER Haas Alarm Description: Tool number must be between 1 and value in Parameter 65 for tool changer.
Haas Alarm: 327 NO LOOP FOR M CODE EXCEPT M97, 98
Alarm: 327 NO LOOP FOR M CODE EXCEPT M97, 98 Haas Alarm Description: L code not required here. Remove L Code.
Haas Alarm: 326 G04 WITHOUT P CODE
Alarm: 326 G04 WITHOUT P CODE Haas Alarm Description: Put a Pn.n for seconds or a Pn for milliseconds.
Haas Alarm: 325 QUEUE FULL
Alarm: 325 QUEUE FULL Haas Alarm Description: Cycle power on the machine. If the alarm reoccurs, call your dealer and report the sequence of events that led to the alarm.
Haas Alarm: 324 DELAY TIME RANGE ERROR
Alarm: 324 DELAY TIME RANGE ERROR Haas Alarm Description: P code in G04 is greater than or equal to 1000 seconds (over 999999 milliseconds). This alarm can also be generated…
Haas Alarm: 323 ATM CRC ERROR – Haas Mill
Alarm: 323 ATM CRC ERROR – Haas Mill Haas Alarm Description: Advanced Tool Management (ATM) variables lost maybe by low battery. Check for a low battery and low battery alarm.
Haas Alarm: 322 SUB PROG WITHOUT M99
Alarm: 322 SUB PROG WITHOUT M99 Haas Alarm Description: Add M99 code to end of program called as a subroutine. Check program.
Haas Alarm: 321 AUTO OFF ALARM
Alarm: 321 AUTO OFF ALARM Haas Alarm Description: Occurs in debug mode only.
Haas Alarm: 320 NO FEED RATE
Alarm: 320 NO FEED RATE Haas Alarm Description: Must have an F code commanded for interpolation functions. For G93 inverse time, there must be an F code on each G01…
Haas Alarm: 319 A OVER TRAVEL RANGE
Alarm: 319 A OVER TRAVEL RANGE Haas Alarm Description: Commanded A-axis move would exceed the machine travel. Machine coordinates are in negative direction. This indicates either an error in the…
Haas Alarm: 318 Z OVER TRAVEL RANGE
Alarm: 318 Z OVER TRAVEL RANGE Haas Alarm Description: Commanded Z-axis move would exceed the machine travel. Machine coordinates are in negative direction. This indicates either an error in the…
Haas Alarm: 317 Y OVER TRAVEL RANGE – Haas Mill
Alarm: 317 Y OVER TRAVEL RANGE – Haas Mill Haas Alarm Description: Commanded Y-axis move would exceed machine travel. Machine coordinates are in negative direction. This indicates either an error…
Haas Alarm: 317 Y OVER TRAVEL RANGE – Haas Lathe
Alarm: 317 Y OVER TRAVEL RANGE – Haas Lathe Haas Alarm Description: Commanded Y-axis move would exceed machine travel. Machine coordinates are in negative direction. This indicates either an error…
Haas Alarm: 316 X OVER TRAVEL RANGE
Alarm: 316 X OVER TRAVEL RANGE Haas Alarm Description: Commanded X-axis move would exceed the machine travel. Machine coordinates are in negative direction. This indicates either an error in the…
Haas Alarm: 315 INVALID P CODE IN M98, M97, M96, G47 OR G65 – Haas Mill
Alarm: 315 INVALID P CODE IN M98, M97, M96, G47 OR G65 – Haas Mill Haas Alarm Description: P code must be the name of a program stored in memory…
Haas Alarm: 315 INVALID P CODE IN M97, M98 OR M99 – Haas Lathe
Alarm: 315 INVALID P CODE IN M97, M98 OR M99 – Haas Lathe Haas Alarm Description: An invalid P Code has been detected in M97, M98, M99, M133, M134, or…
Haas Alarm: 314 SUBPROGRAM NOT IN MEMORY
Alarm: 314 SUBPROGRAM NOT IN MEMORY Haas Alarm Description: Check that a sub-program called by the P code in M98 or G65 is in memory. When calling a sub program…
Haas Alarm: 313 NO P CODE IN M96, M97, M98, M143, M144, or G65
Alarm: 313 NO P CODE IN M96, M97, M98, M143, M144, or G65 Haas Alarm Description: M96, M97, M98 or G65 must put subprogram number in P code. P0 for…
Haas Alarm: 312 PROGRAM END
Alarm: 312 PROGRAM END Haas Alarm Description: End of subroutine reached before M99. Need an M99 to return from subroutine. Check your sub routine or sub program for M99. Sub…
Haas Alarm: 311 UNKNOWN CODE
Alarm: 311 UNKNOWN CODE Haas Alarm Description: Program contained a line or code that is not understood. Check your program.
Haas Alarm: 310 INVALID G CODE
Alarm: 310 INVALID G CODE Haas Alarm Description: ALID G CODE – G code not defined and is not a macro call check parameters 91 through 100. Alias G-code not…
Haas Alarm: 309 EXCEEDED MAX FEEDRATE
Alarm: 309 EXCEEDED MAX FEEDRATE Haas Alarm Description: Use a feed rate less than or equal to parameter 59. Check setting 9 for correct dimensional units, this can be caused…
Haas Alarm: 308 INVALID TOOL OFFSET – Haas Lathe
Alarm: 308 INVALID TOOL OFFSET – Haas Lathe Haas Alarm Description: A tool offset not within the range of the control was used.
Haas Alarm: 307 SUBROUTINE NESTING TOO DEEP
Alarm: 307 SUBROUTINE NESTING TOO DEEP Haas Alarm Description: Subprogram nesting is limited to twenty levels. Simplify your program by using fewer subroutines.
Haas Alarm: 306 INVALID I,J,K, OR Q IN CANNED CYCLE
Alarm: 306 INVALID I,J,K, OR Q IN CANNED CYCLE Haas Alarm Description: I, J, K, and Q variables in a canned cycle must be greater than zero. Check your program.
Haas Alarm: 305 INVALID Q IN CANNED CYCLE
Alarm: 305 INVALID Q IN CANNED CYCLE Haas Alarm Description: Q variable in a canned cycle cannot be zero. Check your program.
Haas Alarm: 304 INVALID I,J OR K IN G02 OR G03
Alarm: 304 INVALID I,J OR K IN G02 OR G03 Haas Alarm Description: Radius at start and end must match radius at end of arc with an accuracy of 0.0010…
Haas Alarm: 303 INVALID X, Y OR Z IN G02 OR G03 – Haas Mill
Alarm: 303 INVALID X, Y OR Z IN G02 OR G03 – Haas Mill Haas Alarm Description: Intersection points in G02 and G03 start and end must have an accuracy…