Haas Alarms

Haas Alarms – Haas Alarm Codes with description.

Haas Alarm: 267 TOOL DOOR OUT OF POSITION – Haas Mill

Alarm: 267 TOOL DOOR OUT OF POSITION – Haas Mill Haas Alarm Description: This alarm will be generated on a horizontal mill during a tool change when Parameter 278, TL…

Haas Alarm: 266 TOOL CHANGER FAULT – Haas Mill

Alarm: 266 TOOL CHANGER FAULT – Haas Mill Haas Alarm Description: Run Tool Changer Recovery.

Haas Alarm: 265 MACRO VARIABLE FILE CRC ERROR

Alarm: 265 MACRO VARIABLE FILE CRC ERROR Haas Alarm Description: Macro variable file has a CRC error. Indicates a loss of memory. Possible corrupted file or processor board problem.

Haas Alarm: 264 ROTARY CRC MISSING

Alarm: 264 ROTARY CRC MISSING Haas Alarm Description: Rotary table parameters have no CRC when loading from disk or RS-232.

Haas Alarm: 263 LEAD SCREW CRC MISSING

Alarm: 263 LEAD SCREW CRC MISSING Haas Alarm Description: Lead screw compensation tables have no CRC when loading from disk or RS-232.

Haas Alarm: 262 PARAMETER CRC MISSING

Alarm: 262 PARAMETER CRC MISSING Haas Alarm Description: RS-232 or disk read of parameter had no CRC when loading from disk or RS-232.

Haas Alarm: 261 ROTARY CRC ERROR

Alarm: 261 ROTARY CRC ERROR Haas Alarm Description: Rotary table saved parameters (used by Settings 30, 78) have a CRC error. Indicates a loss of memory – possible processor board…

Haas Alarm: 260 LANGUAGE CRC

Alarm: 260 LANGUAGE CRC Haas Alarm Description: Indicates Flash memory has been corrupted or damaged. Please reload foreign language files.

Haas Alarm: 259 LANGUAGE VERSION

Alarm: 259 LANGUAGE VERSION Haas Alarm Description: Problem with language files. Please reload foreign language files.

Haas Alarm: 258 INVALID DPRNT FORMAT

Alarm: 258 INVALID DPRNT FORMAT Haas Alarm Description: Macro DPRNT statement not structured properly, check the formatting of the DPRNT commands.

Haas Alarm: 257 PROG DATA ERROR

Alarm: 257 PROG DATA ERROR Haas Alarm Description: Possible corrupt program. Save all programs to disk, delete all, and then reload. If the error persists, programs may have to be…

Haas Alarm: 256 CURRENT TOOL UNKNOWN – Haas Mill

Alarm: 256 CURRENT TOOL UNKNOWN – Haas Mill Haas Alarm Description: Current tool information has been lost. This is most likely due to reinitialization. It is likely that the next…

Haas Alarm: 255 NO TOOL IN SPINDLE – Haas Mill

Alarm: 255 NO TOOL IN SPINDLE – Haas Mill Haas Alarm Description: There is an invalid tool number in the spindle entry of the Pocket-Tool table. The spindle entry cannot…

Haas Alarm: 254 SPINDLE MOTOR OVERHEAT

Alarm: 254 SPINDLE MOTOR OVERHEAT Haas Alarm Description: Motor driving spindle is too hot. This alarm is only generated in machines equipped with a Haas vector drive. The spindle motor…

Haas Alarm: 253 ELECTRONICS OVERHEAT

Alarm: 253 ELECTRONICS OVERHEAT Haas Alarm Description: The control box temperature has exceeded 140° F (60° C). This can be caused by an electronics problem, high room temperature, or clogged…

Haas Alarm: 252 MEMORY OVERFLOW

Alarm: 252 MEMORY OVERFLOW Haas Alarm Description: Possible corrupt program. Save all programs to disk, delete all, and then reload. If the error persists, programs may have to be searched…

Haas Alarm: 251 PROG DATA STRUCT ERROR

Alarm: 251 PROG DATA STRUCT ERROR Haas Alarm Description: Possible corrupt program. Save all programs to disk, delete all, and then reload. If the error persists, programs may have to…

Haas Alarm: 250 PROG DATA ERROR

Alarm: 250 PROG DATA ERROR Haas Alarm Description: Possible corrupt program. Save all programs to disk, delete all, and then reload. If the error persists, programs may have to be…

Haas Alarm: 249 PROG DATA BEGINS ODD

Alarm: 249 PROG DATA BEGINS ODD Haas Alarm Description: Possible corrupt program. Save all programs to disk, delete all, then reload.

Haas Alarm: 248 NUMBER RANGE ERROR

Alarm: 248 NUMBER RANGE ERROR Haas Alarm Description: Number entry is out of range. This could be caused by too many digits in an alphabetical address or macro variable. The…

Haas Alarm: 247 CURSOR DATA BASE ERROR

Alarm: 247 CURSOR DATA BASE ERROR Haas Alarm Description: Cycle power on the machine. If the alarm reoccurs, call your dealer and report the sequence of events that led to…

Haas Alarm: 246 STRING TOO LONG

Alarm: 246 STRING TOO LONG Haas Alarm Description: Input line is too long. The data entry line must be shortened.

Haas Alarm: 245 UNKNOWN CODE

Alarm: 245 UNKNOWN CODE Haas Alarm Description: 245 UNKNOWN CODE – Check input line or data from RS-232. Alarm can occur while editing data into a program or loading from…

Haas Alarm: 244 MISSING (…)

Alarm: 244 MISSING (…) Haas Alarm Description: Comments must begin ‘(‘ and end with a ‘)’. This alarm also occurs with a comment greater than 80 characters long. The erroneous…

Haas Alarm: 243 BAD NUMBER

Alarm: 243 BAD NUMBER Haas Alarm Description: Data entered is not a number.

Haas Alarm: 242 NUMBER FORMAT ERROR-OR TOO LONG

Alarm: 242 NUMBER FORMAT ERROR-OR TOO LONG Haas Alarm Description: Check input file for an improperly formatted number. Number may have too many digits or multiple decimal points. The erroneous…

Haas Alarm: 241 INVALID CODE

Alarm: 241 INVALID CODE Haas Alarm Description: RS-232 load was bad. Data was stored as comment. Check the program received. The erroneous data will be placed on the MESSAGES page…

Haas Alarm: 240 EMPTY PROG OR NO EOB

Alarm: 240 EMPTY PROG OR NO EOB Haas Alarm Description: DNC program not found or no end of program found. Program structure isn’t correct, there needs to be a %…

Haas Alarm: 239 UNKNOWN MOCON1 ALARM

Alarm: 239 UNKNOWN MOCON1 ALARM Haas Alarm Description: Mocon has reported an alarm to the current software. The current version of software was unable to identify the alarm. Check for…

Haas Alarm: 238 AUTOMATIC DOOR FAULT – Haas Mill

Alarm: 238 AUTOMATIC DOOR FAULT – Haas Mill Haas Alarm Description: The automatic door was commanded to operate, but did not complete the operation. The door was: 1) Commanded to…

Haas Alarm: 237 SPINDLE FOLLOWING ERROR

Alarm: 237 SPINDLE FOLLOWING ERROR Haas Alarm Description: The error between the commanded spindle speed and the actual speed has exceeded the maximum allowable (as set in Parameter 184).

Haas Alarm: 236 SPINDLE MOTOR OVERLOAD

Alarm: 236 SPINDLE MOTOR OVERLOAD Haas Alarm Description: The spindle motor is overloaded.

Haas Alarm: 235 SPINDLE Z FAULT

Alarm: 235 SPINDLE Z FAULT Haas Alarm Description: Encoder marker pulse count failure. This alarm usually indicates that the encoder mounted on the spindle has been damaged and encoder position…

Haas Alarm: 234 SPINDLE CABLE FAULT

Alarm: 234 SPINDLE CABLE FAULT Haas Alarm Description: Cable from spindle encoder does not have valid differential signals.

Haas Alarm: 233 JOG HANDLE CABLE FAULT

Alarm: 233 JOG HANDLE CABLE FAULT Haas Alarm Description: Cable from jog handle encoder does not have valid differential signals.