Sinumerik Alarm 310775 Axis %1 drive %2 knee area and saturation area of valve characteristic overlap


Sinumerik Alarm 310775 Axis %1 drive %2 knee area and saturation area of valve characteristic overlap

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
The knee area and the saturation area of the valve characteristic overlap.

Reactions:
– NC not ready.
– Channel not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
The knee area and the saturation area overlap if:
• Positive quadrant: (MD 5465 + MD 5466) > MD 5486
• Negative quadrant: (MD 5468 + MD 5466) > MD 5488 Enter a valid combination in the above drive MD.

Program Continuation:
Clear alarm with the RESET key in all channels. Restart part program.