Sinumerik Alarm 310705 Axis %1 drive %2 monitoring cycle times of axes differ
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The monitoring cycle MD 5002: MONITOR_CYCLE_TIME must be identical for both axes on 2-axis modules.
Reactions:
– NC not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.
Remedy:
Modify MD 5002: MONITOR_CYCLE_TIME for both axes.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens