Sinumerik Alarm 310612 Axis %1 drive %2 force limitation off


Sinumerik Alarm 310612 Axis %1 drive %2 force limitation off

Parameters:
%1 = NC axis number %2 = Drive number

Definitions:
The force limitation is deactivated. Cause: The force limitation is deactivated but:
• The NC has defined a force limit or
• Travel to fixed stop is selected.

Reactions:
– Mode group not ready.
– Channel not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.
Remedy:
Activate power limitation: Modify MD 5241: Set bit 0.

Program Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 310612 Axis %1 drive %2 force limitation off