Sinumerik Alarm 301713 Axis %1 drive %2 resolution SSI direct measuring system invalid


Sinumerik Alarm 301713 Axis %1 drive %2 resolution SSI direct measuring system invalid

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
Configuration of the direct measuring system is faulty for SSI encoder: MD_1032 $MD_ENC_ABS_RESOL_DIRECT must not be 0.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
• Set MD_1032 $MD_ENC_ABS_RESOL_DIRECT to the correct value:
• Rotary encoder: Singleturn resolution (increments per revolution).
• Linear encoder: Resolution of an increment (in nanometers).

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 301713 Axis %1 drive %2 resolution SSI direct measuring system invalid