Sinumerik Alarm 301709 Axis %1 drive %2 submodule with integrated linearization invalid


Sinumerik Alarm 301709 Axis %1 drive %2 submodule with integrated linearization invalid

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
If a submodule with integrated linearization is used, all submodules on the module must use the integrated linearization. A submodule with integrated linearization was found. However, not all submodules have this linearization.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Replace the submodule.

Program Continuation:
Switch control OFF – ON.