Sinumerik Alarm 301707 Axis %1 drive %2 parameterization of modulo value for safe cam (SN) invalid


Sinumerik Alarm 301707 Axis %1 drive %2 parameterization of modulo value for safe cam (SN) invalid

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
The cam modulo range parameterized for a rotary axis via MD 1305: $MD_SAFE_MODULO_RANGE (actual value range for safe cam with rotary axes) violates the rule stating that only integral multiples of 360 degrees may be set.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. Change parameterization of the cam modulo range in MD 1305: $MD_SAFE_MODULO_RANGE (actual value range for safe cam with rotary axes).

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 301707 Axis %1 drive %2 parameterization of modulo value for safe cam (SN) invalid