Sinumerik Alarm 301705 Axis %1 drive %2 distance-coded scale incorrectly parameterized


Sinumerik Alarm 301705 Axis %1 drive %2 distance-coded scale incorrectly parameterized

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
When selecting a distance-coded scale (MD_1011.7=1) it is also necessary to configure a length measuring system (MD_1011.4=1). In addition, the MDs 1040, 1041 and 1042 must not be zero or negative.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. Check and, if necessary, correct MDs 1011: $MD_ACTUAL_VALUE_CONFIG (actual value sensing configuration IM), 1040, 1041 and 1042.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 301705 Axis %1 drive %2 distance-coded scale incorrectly parameterized