Sinumerik Alarm 300770 Axis %1 drive %2 format error


Sinumerik Alarm 300770 Axis %1 drive %2 format error

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
The calculated filter coefficients of a bandstop filter are beyond the range of the internal format. The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

Reactions:
– NC not ready.
– Channel not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. Change the filter setting. The Hotline provides support for accurate troubleshooting. Call the SIEMENS AG, SIMO- DRIVE Hotline.

Program Continuation:
Clear alarm with the RESET key in all channels. Restart part program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 300770 Axis %1 drive %2 format error