Sinumerik Alarm 300762 Axis %1 drive %2 emergency retraction mode/generator mode already active


Sinumerik Alarm 300762 Axis %1 drive %2 emergency retraction mode/generator mode already active

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
Emergency retraction or generator mode already active. The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

Reactions:
– NC not ready.
– Channel not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. Check parameterization/ machine data.

Program Continuation:
Clear alarm with the RESET key in all channels. Restart part program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 300762 Axis %1 drive %2 emergency retraction mode/generator mode already active