Sinumerik Alarm 300757 Axis %1 drive %2 adaption factor of torque limit invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The torque adaptation factor MD 1191: $MD_TORQUE_LIMIT_ADAPT_SERVO (adaptation of servo limit torque) exceeds the format limit.
Reactions:
– NC not ready.
– Channel not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.
Remedy:
Please inform the authorized personnel/service department.
• For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
• For third-party motors: Check and, if necessary, correct the torque adaptation factor MD 1191: $MD_TORQUE_LIMIT_ADAPT_SERVO (adaptation of servo limit torque).
Program Continuation:
Clear alarm with the RESET key in all channels. Restart part program.
References
- Siemens Diagnostics Guide by Siemens