Sinumerik Alarm 300743 Axis %1 drive %2 function not supported on this 611D controller module


Sinumerik Alarm 300743 Axis %1 drive %2 function not supported on this 611D controller module

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
The 611D Performance control module is required for SINUMERIK Safety Integrated. If this hardware has not been installed, this alarm is triggered. The alarm also occurs if 1PH2/4/6 motors are connected and no 611D performance control module is available. The following function is not supported in connection with 611D Comfort modules: Motor switchover (MD1013 >0) and MD1100 not equal to MD2100. Safety Integrated: Booting is interrupted, the pulses remain disabled. The 611D Performance control module is required for SINUMERIK Safety Integrated. If this hardware has not been installed, this alarm is triggered. This alarm is also triggered if the motors 1PH2/ 4/6 are connected and no 611D Performance control module has been installed. Request: During boot-up of the control.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. Replace the 611D control module. Safety Integrated: Replace the 611D control module.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 300743 Axis %1 drive %2 function not supported on this 611D controller module