Sinumerik Alarm 300726 Axis %1 drive %2 voltage constant is zero


Sinumerik Alarm 300726 Axis %1 drive %2 voltage constant is zero

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
The value in drive MD 1114: $MD_EMF_VOLTAGE is set to zero.

Reactions:
– NC not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. For standard motors: Reset the drive (delete the bootfile) and repeat the startup. For third-party motors: Check and, if necessary, refer to the motor data sheet to correct MD 1114: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current).

Program Continuation:
Switch control OFF – ON.