Sinumerik Alarm 300714 Axis %1 drive %2 power section code invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The code number of the power section entered in drive MD 1106: $MD_INVERTER_CODE (power section code number) does not match the power section in the drive configuration display (MD 13020: $MC_DRIVE_INVERTER_CODE).
Reactions:
– NC not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.
Remedy:
Please inform the authorized personnel/service department. Delete modified machine data (e.g. controller data). Reset the drive (delete the bootfile) and repeat the startup.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens