Sinumerik Alarm 300701 Axis %1 drive %2 start-up required
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
This alarm appears when installing and starting up for the first time without valid 611D machine data!
Reactions:
– NC not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.
Remedy:
Please inform the authorized personnel/service department.
• Reset motor data.
• Back up boot drive.
• Repeat the Power ON.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens