Sinumerik Alarm 300009 Axis %1 drive %2 measuring circuit %3 wrong measuring circuit type (type %4 used)


Sinumerik Alarm 300009 Axis %1 drive %2 measuring circuit %3 wrong measuring circuit type (type %4 used)

Parameters:
%1 = NC axis number
%2 = Drive number
%3 = Measuring circuit number
%4 = Measuring circuit type

Definitions:
The available, displayed actual value module on the drive FBG cannot process the signal type that was stated via the axis-specific machine data 30240 ENC_TYPE [e]=S (e … encoder index – the position control works with this encoder, E … , S … signal type of the actual value encoder – 0 … simulation axis without hardware, 1 … raw encoder signals, 2 … rectangle signals).

Reactions:
– NC not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
Please inform the authorized personnel/service department. Set MD 30240 ENC_TYPE [e] to 1 (0 should only be entered for pure simulation axes which are to travel in the actual-value display only).

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 300009 Axis %1 drive %2 measuring circuit %3 wrong measuring circuit type (type %4 used)