Sinumerik Alarm 20095 Axis %1 illegal torque, current torque %2


Sinumerik Alarm 20095 Axis %1 illegal torque, current torque %2

Parameters:
%1 = Axis name, spindle number
%2 = Current holding torque when brake test selected

Definitions:
The current holding torque, when brake test selected, cannot be attained with the present parameterization of the brake test.

Reactions:
– Alarm display.

Remedy:
Check the parameterization for the brake test function check:
• The torque for the counterweight in the drive machine data 1192 should be nearly the same as the current holding torque. The current holding torque is displayed in the alarm text.
• The torque set for the MA_BRAKETEST_TORQUE must be greater than the current holding torque.

Program Continuation:
Clear alarm with the Delete key or NC START.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 20095 Axis %1 illegal torque, current torque %2