Sinumerik Alarm 112300 Tool management type 2 not possible. Magazine not completely loaded.
Definitions:
The magazine is not completely loaded with tools. In the magazine of tool management type 2, the number of tools specified in machine data 18082 has to be created.
Reactions:
– Alarm display.
Remedy:
Installation and start-up: Create the correct number of tools.
Program Continuation:
Internal
References