Sinumerik Alarm 112046 Main contour cannot be bypassed
Definitions:
The pocket contour cannot be bypassed with the specified milling cutter. Residual material will remain. The program can be started. This alarm is only a warning.
Reactions:
– Alarm display.
Remedy:
By using a smaller milling cutter, the pocket contour could be bypassed.
Program Continuation:
Internal
References
- Siemens Diagnostics Guide by Siemens