Sinumerik Alarm 10701 Channel %1 block %2 channel-specific protection zone %3 violated during automatic or MDA mode


Sinumerik Alarm 10701 Channel %1 block %2 channel-specific protection zone %3 violated during automatic or MDA mode

Parameters:
%1 = Channel number
%2 = Block number
%3 = Protection zone number

Definitions:
The work piece-related channel-specific protection zone has been violated. Note that another tool-related protection zone is still active. The workpiece-related protected area can be traversed after a new NC Start.

Reactions:
– Alarm display.
– Interface signals are set.
– Local alarm reaction.
– NC Stop on alarm.

Remedy:
Protection zone can be traversed after a new NC Start.

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 10701 Channel %1 block %2 channel-specific protection zone %3 violated during automatic or MDA mode