Sinumerik Alarm 16010 Channel %1 block %2 machining stop after lift fast
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
LIFTFAST without interrupt routine (Asup) has been programmed. The channel is stopped after the lift motion has been carried out.
Reactions:
– Alarm display.
– Interface signals are set.
– Interpreter stop
– NC Start disable in this channel.
Remedy:
After the channel stop, the axes must be retracted manually in JOG and the program aborted with Reset.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens