Haas Alarms

Haas Alarms – Haas Alarm Codes with description.

Haas Alarm: 688 U AXIS Z CH MISSING – Haas Mill

Alarm: 688 U AXIS Z CH MISSING – Haas Mill Haas Alarm Description: Z Reference signal from encoder was not received as expected. Can be caused by loose connections, encoder…

Haas Alarm: 687 U MOTOR Z FAULT – Haas Mill

Alarm: 687 U MOTOR Z FAULT – Haas Mill Haas Alarm Description: Encoder marker pulse count failure. It usually indicates that encoder has been damaged and encoder position data is…

Haas Alarm: 686 W MOTOR Z FAULT – Haas Mill

Alarm: 686 W MOTOR Z FAULT – Haas Mill Haas Alarm Description: Encoder marker pulse count failure. It usually indicates that encoder has been damaged and encoder position data is…

Haas Alarm: 685 V MOTOR Z FAULT – Haas Mill

Alarm: 685 V MOTOR Z FAULT – Haas Mill Haas Alarm Description: Encoder marker pulse count failure. It usually indicates that encoder has been damaged and encoder position data is…

Haas Alarm: 684 TT or B AXIS LINEAR SCALE Z FAULT – Haas Mill

Alarm: 684 TT or B AXIS LINEAR SCALE Z FAULT – Haas Mill Haas Alarm Description: Encoder marker pulse count failure. This alarm usually indicates that the Z Fault encoder…

Haas Alarm: 683 TT or B AXIS DISABLED – Haas Mill

Alarm: 683 TT or B AXIS DISABLED – Haas Mill Haas Alarm Description: Parameter has disabled this axis.

Haas Alarm: 682 TT or B TRANSITION FAULT – Haas Mill

Alarm: 682 TT or B TRANSITION FAULT – Haas Mill Haas Alarm Description: Illegal transition of count pulses in B-axis. This alarm usually indicates that the encoder has been damaged…

Haas Alarm: 681 TT or B PHASING ERROR – Haas Mill

Alarm: 681 TT or B PHASING ERROR – Haas Mill Haas Alarm Description: Error occurred in phasing initialization of brushless motor. Can be caused by a bad encoder or a…

Haas Alarm: 680 TT or B CABLE FAULT – Haas Mill

Alarm: 680 TT or B CABLE FAULT – Haas Mill Haas Alarm Description: Cable from TT or B-axis encoder does not have valid differential signals.

Haas Alarm: 679 TT or B ZERO RET MARGIN TOO SMALL – Haas Mill

Alarm: 679 TT or B ZERO RET MARGIN TOO SMALL – Haas Mill Haas Alarm Description: This alarm will occur if the home/limit switches move or are misadjusted. This alarm…

Haas Alarm: 678 TT or B AXIS DRIVE FAULT – Haas Mill

Alarm: 678 TT or B AXIS DRIVE FAULT – Haas Mill Haas Alarm Description: Current in TT or B servo motor beyond limit. Possibly caused by a stalled or overloaded…

Haas Alarm: 677 TT or B AXIS Z CH MISSING – Haas Mill

Alarm: 677 TT or B AXIS Z CH MISSING – Haas Mill Haas Alarm Description: Z Reference signal from encoder was not received as expected. Can be caused by loose…

Haas Alarm: 676 TT or B MOTOR Z FAULT – Haas Mill

Alarm: 676 TT or B MOTOR Z FAULT – Haas Mill Haas Alarm Description: Encoder marker pulse count failure. It usually indicates that the encoder has been damaged and encoder…

Haas Alarm: 675 TT or B-AXIS MOTOR OVERHEAT – Haas Mill

Alarm: 675 TT or B-AXIS MOTOR OVERHEAT – Haas Mill Haas Alarm Description: Servo motor overheat. The temperature sensor in the motor indicates over 150° F. Can be caused by…

Haas Alarm: 674 TT or B SERVO OVERLOAD – Haas Mill

Alarm: 674 TT or B SERVO OVERLOAD – Haas Mill Haas Alarm Description: Excessive load on TT or B-axis motor. This can occur if the load on the motor over…

Haas Alarm: 673 TT or B SERVO ERROR TOO LARGE – Haas Mill

Alarm: 673 TT or B SERVO ERROR TOO LARGE – Haas Mill Haas Alarm Description: Too much load or speed on TT or B-axis motor. Difference between motor position and…

Haas Alarm: 671 TT or B LIMIT SWITCH – Haas Mill

Alarm: 671 TT or B LIMIT SWITCH – Haas Mill Haas Alarm Description: Axis hit limit switch or switch disconnected. The stored stroke limits should stop the slides before they…

Haas Alarm: 669 W AXIS LINEAR SCALE Z FAULT – Haas Mill

Alarm: 669 W AXIS LINEAR SCALE Z FAULT – Haas Mill Haas Alarm Description: Encoder marker pulse count failure. This alarm usually indicates that the Z Fault encoder has been…

Haas Alarm: 670 TT or B OVER TRAVEL RANGE – Haas Mill

Alarm: 670 TT or B OVER TRAVEL RANGE – Haas Mill Haas Alarm Description: Commanded TT or B-axis move would exceed the allowed machine range. Machine coordinates are in the…

Haas Alarm: 668 V AXIS LINEAR SCALE Z FAULT – Haas Mill

Alarm: 668 V AXIS LINEAR SCALE Z FAULT – Haas Mill Haas Alarm Description: Encoder marker pulse count failure. This alarm usually indicates that the Z Fault encoder has been…

Haas Alarm: 667 U AXIS LINEAR SCALE Z FAULT – Haas Mill

Alarm: 667 U AXIS LINEAR SCALE Z FAULT – Haas Mill Haas Alarm Description: Encoder marker pulse count failure. This alarm usually indicates that the Z Fault encoder has been…

Haas Alarm: 666 W AXIS DISABLED

Alarm: 666 W AXIS DISABLED Haas Alarm Description: Parameter has disabled this axis.

Haas Alarm: 665 V AXIS DISABLED – Haas Mill

Alarm: 665 V AXIS DISABLED – Haas Mill Haas Alarm Description: Parameter has disabled this axis.

Haas Alarm: 665 V AXIS DISABLED – Haas Lathe

Alarm: 665 V AXIS DISABLED – Haas Lathe Haas Alarm Description: Parameter has disabled bar feeder.

Haas Alarm: 664 U AXIS DISABLED

Alarm: 664 U AXIS DISABLED Haas Alarm Description: Parameter has disabled this axis.

Haas Alarm: 663 W TRANSITION FAULT – Haas Mill

Alarm: 663 W TRANSITION FAULT – Haas Mill Haas Alarm Description: Illegal transition of count pulses in W-axis. This alarm usually indicates that the encoder has been damaged and encoder…

Haas Alarm: 662 V TRANSITION FAULT – Haas Mill

Alarm: 662 V TRANSITION FAULT – Haas Mill Haas Alarm Description: Illegal transition of count pulses in V-axis. This alarm usually indicates that the encoder has been damaged and encoder…

Haas Alarm: 661 U TRANSITION FAULT – Haas Mill

Alarm: 661 U TRANSITION FAULT – Haas Mill Haas Alarm Description: Illegal transition of count pulses in U-axis. This alarm usually indicates that the encoder has been damaged and encoder…

Haas Alarm: 660 W PHASING ERROR – Haas Mill

Alarm: 660 W PHASING ERROR – Haas Mill Haas Alarm Description: Error occurred in phasing initialization of brushless motor. Can be caused by a bad encoder, or a cabling error.

Haas Alarm: 659 NOT ONE AXIS MOVE WITH CHAMFERING – Haas Lathe

Alarm: 659 NOT ONE AXIS MOVE WITH CHAMFERING – Haas Lathe Haas Alarm Description: Consecutive blocks commanded with chamfering or corner rounding, for example: G01 Xb Kk G01 Zb Ii….

Haas Alarm: 659 V PHASING ERROR – Haas Mill

Alarm: 659 V PHASING ERROR – Haas Mill Haas Alarm Description: Error occurred in phasing initialization of brushless motor. Can be caused by a bad encoder, or a cabling error.

Haas Alarm: 658 U PHASING ERROR – Haas Mill

Alarm: 658 U PHASING ERROR – Haas Mill Haas Alarm Description: Error occurred in phasing initialization of brushless motor. Can be caused by a bad encoder, or a cabling error.

Haas Alarm: 658 INVALID MOVE AFTER CHAMFERING – Haas Lathe

Alarm: 658 INVALID MOVE AFTER CHAMFERING – Haas Lathe Haas Alarm Description: The command after the block commanded with chamfering or corner rounding is either missing or wrong. There must…

Haas Alarm: 657 W CABLE FAULT – Haas Mill

Alarm: 657 W CABLE FAULT – Haas Mill Haas Alarm Description: Cable from W-axis encoder does not have valid differential signals.

Haas Alarm: 657 NOT ONE AXIS MOVE WITH CHAMFERING – Haas Lathe

Alarm: 657 NOT ONE AXIS MOVE WITH CHAMFERING – Haas Lathe Haas Alarm Description: Consecutive blocks commanded with chamfering or corner rounding, for example: G01 Xb Kk G01 Zb Ii….