Haas Alarms

Haas Alarms – Haas Alarm Codes with description.

Haas Alarm: 624 COMMAND NOT ALLOWED IN G14 MODE – Haas Lathe

Alarm: 624 COMMAND NOT ALLOWED IN G14 MODE – Haas Lathe Haas Alarm Description: G87 and G88 are not supported in G14 mode.

Haas Alarm: 623 INVALID CODE IN G112 – Haas Lathe

Alarm: 623 INVALID CODE IN G112 – Haas Lathe Haas Alarm Description: Only G0 to G3 and G17 are used in G112. G113 cancels G112. No incremental axes are used…

Haas Alarm: 622 TOOL ARM FAULT – Haas Mill

Alarm: 622 TOOL ARM FAULT – Haas Mill Haas Alarm Description: This alarm is generated by the tool changer if the arm is not at the Origin position or the…

Haas Alarm: 622 C AXIS ENGAGEMENT FAILURE – Haas Lathe

Alarm: 622 C AXIS ENGAGEMENT FAILURE – Haas Lathe Haas Alarm Description: The C-axis failed to engage or disengage in the time specified in Parameter 572. Either gears are not…

Haas Alarm: 621 C OVER TRAVEL RANGE

Alarm: 621 C OVER TRAVEL RANGE Haas Alarm Description: C-axis will exceed stored stroke limits. This is a negative direction parameter and is machine zero in the positive direction. This…

Haas Alarm: 620 C AXIS DISABLED

Alarm: 620 C AXIS DISABLED Haas Alarm Description: Parameters have disabled this axis.

Haas Alarm: 619 STROKE EXCEEDS START POSITION – Haas Lathe

Alarm: 619 STROKE EXCEEDS START POSITION – Haas Lathe Haas Alarm Description: Stock removal stroke in canned cycle projects past start position. Change start position.

Haas Alarm: 618 W-AXIS MOTOR OVERHEAT – Haas Mill

Alarm: 618 W-AXIS MOTOR OVERHEAT – Haas Mill Haas Alarm Description: Servo motor overheat. Temperature sensor in motor indicates over 150° F (65° C). Can be caused by overload of…

Haas Alarm: 618 INVALID ADDRESS VALUE – Haas Lathe

Alarm: 618 INVALID ADDRESS VALUE – Haas Lathe Haas Alarm Description: An address code is being used incorrectly; a negative value being used for an address code that should be…

Haas Alarm: 617 V-AXIS MOTOR OVERHEAT – Haas Mill

Alarm: 617 V-AXIS MOTOR OVERHEAT – Haas Mill Haas Alarm Description: Servo motor overheat. Temperature sensor in motor indicates over 150° F (65° C). Can be caused by overload of…

Haas Alarm: 617 MISSING ADDRESS CODE – Haas Lathe

Alarm: 617 MISSING ADDRESS CODE – Haas Lathe Haas Alarm Description: A canned cycle using P & Q is already executing. A canned cycle cannot be executed by another PQ…

Haas Alarm: 616 U-AXIS MOTOR OVERHEAT – Haas Mill

Alarm: 616 U-AXIS MOTOR OVERHEAT – Haas Mill Haas Alarm Description: Servo motor overheat. Temperature sensor in motor indicates over 150° F (65° C). Can be caused by overload of…

Haas Alarm: 616 CANNED CYCLE USING P & Q IS ACTIVE – Haas Lathe

Alarm: 616 CANNED CYCLE USING P & Q IS ACTIVE – Haas Lathe Haas Alarm Description: A canned cycle using P & Q is already executing. A canned cycle cannot…

Haas Alarm: 615 W SERVO OVERLOAD – Haas Mill

Alarm: 615 W SERVO OVERLOAD – Haas Mill Haas Alarm Description: Excessive load on W-axis motor. This can occur if the load on the motor over a period of several…

Haas Alarm: 615 NO INTERSECTION TO OFFSETS IN CC – Haas Lathe

Alarm: 615 NO INTERSECTION TO OFFSETS IN CC – Haas Lathe Haas Alarm Description: While cutter comp was in effect, a geometry was encountered whose compensated paths had no solution…

Haas Alarm: 614 V SERVO OVERLOAD – Haas Mill

Alarm: 614 V SERVO OVERLOAD – Haas Mill Haas Alarm Description: Excessive load on V-axis motor. This can occur if the load on the motor over a period of several…

Haas Alarm: 613 COMMAND NOT ALLOWED IN CUTTER COMPENSATION

Alarm: 613 COMMAND NOT ALLOWED IN CUTTER COMPENSATION Haas Alarm Description: At least one command in the highlighted block cannot be executed while cutter compensation is active. Block Delete characters…

Haas Alarm: 612 U SERVO OVERLOAD – Haas Mill

Alarm: 612 U SERVO OVERLOAD – Haas Mill Haas Alarm Description: Excessive load on U-axis motor. This can occur if the load on the motor over a period of several…

Haas Alarm: 612 G71/G72 TYPE II ALARM – Haas Lathe

Alarm: 612 G71/G72 TYPE II ALARM – Haas Lathe Haas Alarm Description: This alarm is similar to Alarm 611, but indicates that the control has selected Type II roughing.

Haas Alarm: 611 W SERVO ERROR TOO LARGE – Haas Mill

Alarm: 611 W SERVO ERROR TOO LARGE – Haas Mill Haas Alarm Description: Too much load or speed on W-axis motor. The difference between the motor position and the commanded…

Haas Alarm: 611 G71/G72 TYPE I ALARM – Haas Lathe

Alarm: 611 G71/G72 TYPE I ALARM – Haas Lathe Haas Alarm Description: When G71 or G72 is executing and the control detects a problem in the defined PQ path. It…

Haas Alarm: 610 V SERVO ERROR TOO LARGE – Haas Mill

Alarm: 610 V SERVO ERROR TOO LARGE – Haas Mill Haas Alarm Description: Too much load or speed on V-axis motor. The difference between the motor position and the commanded…

Haas Alarm: 610 G71/G72 DOMAIN NESTING EXCEEDED – Haas Lathe

Alarm: 610 G71/G72 DOMAIN NESTING EXCEEDED – Haas Lathe Haas Alarm Description: The number of troughs nested has exceeded the control limit. Currently, no more than 10 levels of trough…

Haas Alarm: 609 U SERVO ERROR TOO LARGE – Haas Mill

Alarm: 609 U SERVO ERROR TOO LARGE – Haas Mill Haas Alarm Description: Too much load or speed on U-axis motor. The difference between the motor position and the commanded…

Haas Alarm: 609 TAILSTOCK RESTRICTED ZONE – Haas Lathe

Alarm: 609 TAILSTOCK RESTRICTED ZONE – Haas Lathe Haas Alarm Description: This alarm is caused by an axis moving into the tailstock restricted zone during program execution. To eliminate the…

Haas Alarm: 608 INVALID Q CODE

Alarm: 608 INVALID Q CODE Haas Alarm Description: Q address code used as a numeric value that was incorrect in the context used. In M96 Q can reference only bits…

Haas Alarm: 607 INVALID W CODE – Haas Lathe

Alarm: 607 INVALID W CODE – Haas Lathe Haas Alarm Description: In the context that the W code was used it had an invalid value. Was it positive?

Haas Alarm: 606 INVALID A CODE – Haas Lathe

Alarm: 606 INVALID A CODE – Haas Lathe Haas Alarm Description: An invalid angle for linear interpolation was specified. This will occur in a G01 block if the A address…

Haas Alarm: 605 W LIMIT SWITCH – Haas Mill

Alarm: 605 W LIMIT SWITCH – Haas Mill Haas Alarm Description: Axis hit limit switch or switch disconnected. The stored stroke limits should stop the slides before they hit the…

Haas Alarm: 605 INVALID TOOL NOSE ANGLE – Haas Lathe

Alarm: 605 INVALID TOOL NOSE ANGLE – Haas Lathe Haas Alarm Description: An invalid angle for the cutting tool tip was specified. This will occur in a G76 block if…

Haas Alarm: 604 V LIMIT SWITCH – Haas Mill

Alarm: 604 V LIMIT SWITCH – Haas Mill Haas Alarm Description: Axis hit limit switch or switch disconnected. The stored stroke limits should stop the slides before they hit the…

Haas Alarm: 604 NON-MONOTONOUS ARC IN PQ BLOCK – Haas Lathe

Alarm: 604 NON-MONOTONOUS ARC IN PQ BLOCK – Haas Lathe Haas Alarm Description: A non-monotonic arc was found in a PQ block. This will occur in PQ blocks within a…

Haas Alarm: 603 U LIMIT SWITCH – Haas Mill

Alarm: 603 U LIMIT SWITCH – Haas Mill Haas Alarm Description: Axis hit limit switch or switch disconnected. The stored stroke limits should stop the slides before they hit the…

Haas Alarm: 603 NON-MONOTONOUS PQ BLOCKS IN Z – Haas Lathe

Alarm: 603 NON-MONOTONOUS PQ BLOCKS IN Z – Haas Lathe Haas Alarm Description: The path defined by PQ was not monotonic in the Z-axis. A monotonic Path is one that…

Haas Alarm: 602 W OVER TRAVEL RANGE – Haas Mill

Alarm: 602 W OVER TRAVEL RANGE – Haas Mill Haas Alarm Description: Commanded W-axis move would exceed the allowed machine range. Machine coordinates are in the negative direction. This indicates…