Haas Setting 65 Graph Scale (Height)


Haas Setting 65 Graph Scale (Height)

Haas Setting Description
This setting specifies the height of the work area that is displayed on the Graphics mode screen. The default value for this setting is the maximum height, which is the entire machine work area. Using the following formula can set a specific scale:
Total Y travel = Parameter 20 / Parameter 19
Scale = Total Y travel / Setting 65