Haas Alarms

Haas Alarms – Haas Alarm Codes with description.

Haas Alarm: 168 A ZERO RET MARGIN TOO SMALL

Alarm: 168 A ZERO RET MARGIN TOO SMALL Haas Alarm Description: This alarm will occur if the home/limit switches move or are misadjusted. It indicates that the zero return position…

Haas Alarm: 167 Z ZERO RET MARGIN TOO SMALL

Alarm: 167 Z ZERO RET MARGIN TOO SMALL Haas Alarm Description: This alarm will occur if the home/limit switches move or are misadjusted. It indicates that the zero return position…

Haas Alarm: 166 Y ZERO RET MARGIN TOO SMALL

Alarm: 166 Y ZERO RET MARGIN TOO SMALL Haas Alarm Description: This alarm will occur if the home/limit switches move or are misadjusted. It indicates that the zero return position…

Haas Alarm: 165 X ZERO RET MARGIN TOO SMALL

Alarm: 165 X ZERO RET MARGIN TOO SMALL Haas Alarm Description: This alarm will occur if the home/limit switches move or are misadjusted. It indicates that the zero return position…

Haas Alarm: 164 A AXIS DRIVE FAULT

Alarm: 164 A AXIS DRIVE FAULT Haas Alarm Description: Current in A servo motor beyond limit. Possibly caused by a stalled or overloaded motor. The servos are turned off. Can…

Haas Alarm: 163 Z AXIS DRIVE FAULT

Alarm: 163 Z AXIS DRIVE FAULT Haas Alarm Description: Current in Z servo motor beyond limit. Possibly caused by a stalled or overloaded motor. The servos are turned off. Can…

Haas Alarm: 162 Y AXIS DRIVE FAULT

Alarm: 162 Y AXIS DRIVE FAULT Haas Alarm Description: (L) Current in Live Tooling servo motor beyond limit, (M) Current in Y servo motor beyond limit. Possibly caused by a…

Haas Alarm: 161 X AXIS DRIVE FAULT

Alarm: 161 X AXIS DRIVE FAULT Haas Alarm Description: Current in X servo motor beyond limit. Possibly caused by a stalled or overloaded motor. The servos are turned off. Can…

Haas Alarm: 160 LOW VOLTAGE – Haas Mill

Alarm: 160 LOW VOLTAGE Haas Alarm Description: The line voltage to control is too low. This alarm occurs when the AC line voltage drops more than 10% below nominal and…

Haas Alarm: 160 LOW VOLTAGE – Haas Lathe

Alarm: 160 LOW VOLTAGE Haas Alarm Description: The line voltage to control is too low. This alarm occurs when the AC line voltage drops below the voltage specified by Parameter…

Haas Alarm: 159 KEYBOARD FAILURE

Alarm: 159 KEYBOARD FAILURE Haas Alarm Description: Keyboard shorted or button pressed at power on. A power-on test of the membrane keypad has found a shorted button. It can also…

Haas Alarm: 158 VIDEO/KEYBOARD PCB FAILURE

Alarm: 158 VIDEO/KEYBOARD PCB FAILURE Haas Alarm Description: During power-on tests, the control has detected a problem in either the keyboard or the video memory. Call your dealer.

Haas Alarm: 157 MOCON WATCHDOG FAULT

Alarm: 157 MOCON WATCHDOG FAULT Haas Alarm Description: The self-test of the MOCON has failed. Call your dealer. Test +12, -12, and +5 volt power at MOCON PCB. Unreliable power…

Haas Alarm: 156 A AXIS Z CH MISSING

Alarm: 156 A AXIS Z CH MISSING Haas Alarm Description: Z Reference signal from encoder was not received as expected. Can be caused by loose connections, encoder contamination, or parameter…

Haas Alarm: 155 Z AXIS Z CH MISSING

Alarm: 155 Z AXIS Z CH MISSING Haas Alarm Description: Z Reference signal from encoder was not received as expected. All servos are turned off. Can be caused by loose…

Haas Alarm: 154 Y AXIS Z CH MISSING

Alarm: 154 Y AXIS Z CH MISSING Haas Alarm Description: Z Reference signal from encoder was not received as expected. All servos are turned off. Can be caused by loose…

Haas Alarm: 153 X AXIS Z CH MISSING

Alarm: 153 X AXIS Z CH MISSING Haas Alarm Description: Z Reference signal from encoder was not received as expected. All servos are turned off. Can be caused by loose…

Haas Alarm: 152 SELF TEST FAIL

Alarm: 152 SELF TEST FAIL Haas Alarm Description: Control has detected an electronics fault. All motors and solenoids are shut down. This is most likely caused by a fault of…

Haas Alarm: 151 LOW THRU SPINDLE COOLANT – Haas Mill

Alarm: 151 LOW THRU SPINDLE COOLANT Haas Alarm Description: For mills with Through the Spindle Coolant only. This alarm will shut off the coolant spigot, feed, and pump all at…

Haas Alarm: 151 HPC LOW PRESSURE – Haas Lathe

Alarm: 151 HPC LOW PRESSURE Haas Alarm Description: A low coolant pressure condition has been detected. To disable this alarm, set Parameter 209 Common Switch 2 DSBL CLNT IN to…

Haas Alarm: 150 Z AND TOOL INTERLOCKED – Haas Mill

Alarm: 150 Z AND TOOL INTERLOCKED Haas Alarm Description: Tool changer not at home and either the Z or A or B axis (or any combination) is not at machine…

Haas Alarm: 150 I_MODE OUT OF RANGE – Haas Lathe

Alarm: 150 I_MODE OUT OF RANGE Haas Alarm Description: Cycle power on the machine. If the alarm reoccurs, call your dealer and report the sequence of events that led to…

Haas Alarm: 149 SPINDLE TURNING – Haas Mill

Alarm: 149 SPINDLE TURNING Haas Alarm Description: A signal from spindle drive indicating that ‘spindle drive is stopped’ is not present while a tool change operation is going on.

Haas Alarm: 149 SPINDLE TURNING – Haas Lathe

Alarm: 149 SPINDLE TURNING Haas Alarm Description: The machine has detected that the spindle is still turning when it expects it to be stopped. This is most likely cause by…

Haas Alarm: 148 A LIMIT SWITCH

Alarm: 148 A LIMIT SWITCH Haas Alarm Description: Normally disabled for rotary axis.

Haas Alarm: 147 Z LIMIT SWITCH

Alarm: 147 Z LIMIT SWITCH Haas Alarm Description: Axis hit limit switch or switch disconnected. Home switch input changed state while machine was in use. Stored stroke limits should stop…

Haas Alarm: 146 Y LIMIT SWITCH

Alarm: 146 Y LIMIT SWITCH Haas Alarm Description: Live Tooling hit limit switch or switch disconnected. Home switch input changed state while machine was in use. Stored stroke limits should…

Haas Alarm: 145 X LIMIT SWITCH

Alarm: 145 X LIMIT SWITCH Haas Alarm Description: Axis hit limit switch or switch disconnected. Home switch input changed state while machine was in use. Stored stroke limits should stop…

Haas Alarm: 144 TIMEOUT – CALL YOUR DEALER

Alarm: 144 TIMEOUT – CALL YOUR DEALER Haas Alarm Description: Time allocated for use prior to payment exceeded. Call your dealer.

Haas Alarm: 143 SPINDLE ORIENTATION LOST – Haas Mill

Alarm: 143 SPINDLE ORIENTATION LOST Haas Alarm Description: Spindle orientation lost during a tool change operation. This can be caused by failure of encoder, cables, belts, MOCON, or vector drive.

Haas Alarm: 143 SPINDLE ORIENTATION LOST – Haas Lathe

Alarm: 143 SPINDLE ORIENTATION LOST Haas Alarm Description: Spindle orientation lost during a fine spindle control motion. This can be caused by failure of encoder, cables, belts, MOCON, or vector…

Haas Alarm: 142 A-AXIS MOTOR Z FAULT

Alarm: 142 A-AXIS MOTOR Z FAULT Haas Alarm Description: Encoder marker pulse count failure. This alarm usually means that the encoder has been damaged and encoder position data is unreliable….

Haas Alarm: 141 Z-AXIS MOTOR Z FAULT

Alarm: 141 Z-AXIS MOTOR Z FAULT Haas Alarm Description: Encoder marker pulse count failure. This alarm usually means that the encoder has been damaged and encoder position data is unreliable….

Haas Alarm: 140 Y-AXIS MOTOR Z FAULT

Alarm: 140 Y-AXIS MOTOR Z FAULT Haas Alarm Description: Encoder marker pulse count failure. This alarm usually means that the encoder has been damaged and encoder position data is unreliable….

Haas Alarm: 139 X-AXIS MOTOR Z FAULT

Alarm: 139 X-AXIS MOTOR Z FAULT Haas Alarm Description: Encoder marker pulse count failure. This alarm usually means that the encoder has been damaged and encoder position data is unreliable….