Centroid Alarms

Centroid Alarms, Errors Messages

Centroid Alarm 911 Illegal recursion

Centroid Alarm 911 Illegal recursion Cause & Effect Attempt to execute a subprogram or macro that calls itself, either directly or indirectly. Job cancelled. Action Call correct subprogram.

Centroid Alarm 910 No subroutines in MDI

Centroid Alarm 910 No subroutines in MDI Cause & Effect Specified O9100 – O9999 in MDI, which would begin an embedded subprogram. MDI cancelled.

Centroid Alarm 909 Program too long: job canceled

Centroid Alarm 909 Program too long: job canceled Cause & Effect Attempt to run a job over 1MB in length, without the unlimited program size option. Job cancelled. Action Contact…

Centroid Alarm 907 _ axis travel exceeded on line NNNNN

Centroid Alarm 907 _ axis travel exceeded on line NNNNN Cause & Effect Software travel limit would be exceeded by the requested move. Job cancelled. Action Check program, part zero…

Centroid Alarm 906 Warning: unknown arc on line NNNNN

Centroid Alarm 906 Warning: unknown arc on line NNNNN Cause & Effect Position of arc move could not be determined from parameters. Move is done as a linear move; job…

Centroid Alarm 905 Warning: 0 radius arc on line NNNNN

Centroid Alarm 905 Warning: 0 radius arc on line NNNNN Cause & Effect Arc move was specified with a zero radius. Move is done as a linear move; job continues….

Centroid Alarm 903 Warning: No coordinates for G50 on line NNNNN

Centroid Alarm 903 Warning: No coordinates for G50 on line NNNNN Cause & Effect G50 with no axis coordinates to set. Remainder of line processed; job continues. Action Add coordinates.

Centroid Alarm 902 No prior G28 or G30 on line NNNNN

Centroid Alarm 902 No prior G28 or G30 on line NNNNN Cause & Effect G29 with no preceding G28 or G30. Action Add a G29 or G30.

Centroid Alarm 901 Ref. point invalid on line NNNNN

Centroid Alarm 901 Ref. point invalid on line NNNNN Cause & Effect G30 with invalid P value (must be 1 or 2). Job cancelled. Action Change P-value to a 1…

Centroid Alarm 806 Error: No P value on line NNNNN

Centroid Alarm 806 Error: No P value on line NNNNN Cause & Effect P value (dwell time) not specified for G82 or G89. Job cancelled. Action Add a P-value.

Centroid Alarm 805 Error: No Q value on line NNNNN

Centroid Alarm 805 Error: No Q value on line NNNNN Cause & Effect Q value not specified for G73 or G83. Job cancelled. Action Insert a Q-value.

Centroid Alarm 804 Error: Ggg invalid on line NNNNN (gg = 76, 86, 87, 88)

Centroid Alarm 804 Error: Ggg invalid on line NNNNN (gg = 76, 86, 87, 88) Cause & Effect Unimplemented canned cycle requested. Job cancelled. Action Change to a valid Gcode.

Centroid Alarm 803 Error: No Z point on line NNNNN

Centroid Alarm 803 Error: No Z point on line NNNNN Cause & Effect No Z value specified for canned cycle. Job cancelled. Action Add a Z-value.

Centroid Alarm 802 Error: Q = 0 on line NNNNN

Centroid Alarm 802 Error: Q = 0 on line NNNNN Cause & Effect Q value of 0 specified (Q used for G73 and G83 only). Job cancelled. Action Insert a…

Centroid Alarm 801 Error: No R point on line NNNNN

Centroid Alarm 801 Error: No R point on line NNNNN Cause & Effect No R-value specified. Job cancelled. Action Add an R-point.

Centroid Alarm 705 G10 error: No D, H, or P on line NNNNN

Centroid Alarm 705 G10 error: No D, H, or P on line NNNNN Cause & Effect G10 used without D, H, or P to assign value. Job cancelled. Action Add…

Centroid Alarm 704 G10 error: invalid P on line NNNNN

Centroid Alarm 704 G10 error: invalid P on line NNNNN Cause & Effect G10 used with unknown P value. Job cancelled. Action Change P to a valid value.

Centroid Alarm 703 G10 error: invalid H on line NNNNN

Centroid Alarm 703 G10 error: invalid H on line NNNNN Cause & Effect G10 H0 Rxx specified. Job canceled (H0 cannot be set; it is always zero). Action Change H…

Centroid Alarm 702 G10 error: invalid D on line NNNNN

Centroid Alarm 702 G10 error: invalid D on line NNNNN Cause & Effect Job cancelled (D0 cannot be set; it is always zero). Action Change D to a valid value.

Centroid Alarm 701 G10 error: no R-value on line NNNNN

Centroid Alarm 701 G10 error: no R-value on line NNNNN Cause & Effect G10 used with no R-value. Job cancelled. Action Input an R-value.

Centroid Alarm 608 Ref. point move not allowed on line NNNNN

Centroid Alarm 608 Ref. point move not allowed on line NNNNN Cause & Effect G28, G29, or G30 attempted during compensation. Job cancelled. Action Do not use return points with…

Centroid Alarm 607 Set home not allowed on line NNNNN

Centroid Alarm 607 Set home not allowed on line NNNNN Cause & Effect M26 attempted during compensation. Job cancelled. Action Do not use M26 with cutter comp.

Centroid Alarm 606 G53 not allowed on line NNNNN

Centroid Alarm 606 G53 not allowed on line NNNNN Cause & Effect G53 attempted during compensation. Job cancelled.

Centroid Alarm 605 Canned cycle not allowed on line NNNNN

Centroid Alarm 605 Canned cycle not allowed on line NNNNN Cause & Effect Canned cycle attempted during compensation. Job cancelled. Action Do not use cutter comp. with canned cycles.

Centroid Alarm 603 Arc as first uncomp. move on line NNNNN

Centroid Alarm 603 Arc as first uncomp. move on line NNNNN Cause & Effect Arc specified as first move after end of compensation (G40). Job cancelled. Action First move after…

Centroid Alarm 601 Error: no compensation in MDI

Centroid Alarm 601 Error: no compensation in MDI Cause & Effect G41 or G42 entered in MDI. MDI is not canceled, but cutter compensation does NOT go into effect. Remainder…

Centroid Alarm 549 Line too long

Centroid Alarm 549 Line too long Cause & Effect A line in a G/M-code program is too long (more than 1023 characters). Action Shorten the line.

Centroid Alarm 548 String too long

Centroid Alarm 548 String too long Cause & Effect A quoted string was too long (usually a file name was longer than its allowed limit). Action Shorten the file name.

Centroid Alarm 547 Move by counts not allowed

Centroid Alarm 547 Move by counts not allowed Cause & Effect Cutter comp (G41/G42) was on when M128 was specified Action Issue G40 (Cutter comp off) before issuing M128

Centroid Alarm 545 Value out of range

Centroid Alarm 545 Value out of range Cause & Effect Parse error occurred because value was out of range Action Correct the value

Centroid Alarm 544 Too many axes

Centroid Alarm 544 Too many axes Cause & Effect More than 1 axis was specified with M128, OR the Simultaneous Contouring feature is not enabled. Without the Simultaneous Contouring feature,…

Centroid Alarm 543 Missing L parameter

Centroid Alarm 543 Missing L parameter Cause & Effect L code was missing Action Correct program.

Centroid Alarm 542 M22x character limit exceeded

Centroid Alarm 542 M22x character limit exceeded Cause & Effect The resultant formatted string after all the format codes were processed was too long. Action Correct program.

Centroid Alarm 540 M22x variable cannot be read

Centroid Alarm 540 M22x variable cannot be read Cause & Effect A format code was specified in the format string, but its corresponding #variable argument was invalid or there was…

Centroid Alarm 539 M22x variable type mismatch

Centroid Alarm 539 M22x variable type mismatch Cause & Effect A string format code was specified in the format string, but its corresponding #variable argument was numeric OR a numeric…