Okuma Alarm-P 0848 PSCB error


Okuma Alarm-P 0848 PSCB error
An error occurred in the PSC board for can turning lathe.

Code
1->Clock stop error
2->Parity error in compensation data memory(C0)
4->Parity error in compensation data memory(C1)
8->Parity error in deviation data memory
10->Parity error in command data memory
20->Parity error in main memory
40->Cycle over error
80->Loop error

Probable Faulty Locations
Faulty PSC board

Measures to Take
Change the PSC board

Okuma Alarm-P 0848 PSCB error