Okuma Alarm-B 2492 Interrupt program: illegal command


Okuma Alarm-B 2492 Interrupt program: illegal command
The interrupt program is used in a wrong manner.

Index
Saddle name

Character-string
None

Code
1: A command between M940 and M945 is issued during execution of the interrupt program.
2: No interrupt program (O941 to O945) is registered.
3: When interrupt program is executing, though nose R compensation (G41-G42) is effective, RTI command was designated without canceling nose R compensation (G40).

Probable Faulty Locations
. Programming error
. Unregistered interrupt programs

Measures to Take
1: Delete M940 to M945 commands from the interrupt program.
2: Register the programs O941 to O945 in the interrupt program file (A.INT).Then, resupply the power.
3: Check and correct the program.