Okuma Alarm-B 2346 Tool retract interrupt return com.


Okuma Alarm-B 2346 Tool retract interrupt return com.
The interruption return command (RTI) was issued when the tool retract interruption was not activated.
Or, when it is under-cases, RTI-command was performed.
1)Exciting of the tool retract cycle.
2)The tool retract cycle for hob-cutting.
3)The tool retract cycle on G127-mode.
4)The mode differs “the tool retract interruption”and “the interruption return command”.

Object
SYSTEM

Code
1->The RTI command is designated in other than tool retraction interruption mode.
2->The RTI command is designated after the tool interruption during the thread cutting cycle.
3->Tool retract cycle was executed during HOB cutting.
4->The tool retract cycle was ordered on G127-mode.
5->The mode differs “the tool retract interruption”and “the interruption return command”.
(G136/G138, G126/G127, G140/G141)

Probable Faulty Locations
1,2,4,5->Incorrect program
3->Push the button of retract cycle during
HOB cutting.

Related Specifications
Tool retraction cycle

Okuma Alarm-B 2346 Tool retract interrupt return com.