Okuma Alarm-A 1731 Turret index control alarm


Okuma Alarm-A 1731 Turret index control alarm
An alarm occurs with the turret index controller.

Object
SYSTEM

Code
X: Alarm code sent from the turret index controller
2->Unclamp time over
3->Acceleration time over
4->Rotation speed time over
5->Index over
6->Rotation direction error
7->Deceleration time over
8->Creep time over
9->Clamp error
A->Position detection error 1
B->Position detection error 2
D->Neutral time over
E->Communication error
F->Clamp time over

Probable Faulty Locations
1)Program error or error in the command input from the keyboard in the case of code X=E
T14** was issued to the turret with 12 stations.
2)For the code other than it, the turret index controller will be defective, or the mechanical or electrical (EC) system related with the turret index operation is faulty.