Okuma Alarm-A 1473 Actual position initialization error XS-axis


Okuma Alarm-A 1473 Actual position initialization error XS-axis
Xs-axis(cam-axis) has not returned to the zero point correctly.

Index
None

Character-string
None

Code
1->The Xs-axis fails to enter the zero return zone.
2->The zero point is not found.

Probable Faulty Locations
The zero return range signal and the zero return signal are not input.
Faulty optical scale or pulse signal unit.

Measures to Take
Check the input of the zero return range signal and the zero point signal.

Okuma Alarm-A 1473 Actual position initialization error XS-axis