Okuma Alarm-P 0842 Safety monitor spec. error


Okuma Alarm-P 0842 Safety monitor spec. error
Conditions for connecting the safe speed monitor are not met. Or, the guard number in the axis data file for safe speed monitor is out of the allowable setting range.

Code
X
1-> The safe speed monitor connected to the displayed axis is in wrong position.
2-> Values other than 1 to 9 is set as the guard number in the axis data file for safe speed monitor.
3-> Safe speed monitor is not installed though the machine is intended for CE marking.
4-> Safe speed monitor is installed though the machine is not intended for CE marking.
5-> The axis data file for safe speed monitor has two same positions where the safety monitor is connected to the spindle (Mspindle).
6-> The version number of the safe speed monitor is less than 400.
7-> The version number of the safe speed monitor is less than 600.
8-> The safety speed monitor is connected though it is CE marking safety logic specification.

Measures to Take
1) Check the safe speed monitor for connected position.
2) Set a number between 1 to 9 as the guard number in the data file for safe speed monitor.
3) Connect the safe speed monitor.
4) Set the specification code for CE marking. or remove the safe speed monitor.
5) Check the guard number and the entered number in the data file for safe speed monitor.
6) Set the safe speed monitor whose version is more than 400.
7) Set the safe speed monitor whose version is more than 600 when function checking that CE marking is stopping is effective.
8) CE marking safety logic specification is turned off.
Or, the safety speed monitor is removed.