Okuma Alarm-B 2729 No magazine return pot


Okuma Alarm-B 2729 No magazine return pot
The tool cannot be returned because there is no empty pot.

Probable Faulty Locations
The magazine has no empty pot. Tool data is wrongly set on the “*ATC MAGAZINE INFORMATION*” screen in tool data setting mode.
When setting the tool diameter, note that a large diameter tool requires two empty pots arranged side by side while an extra large diameter tool requires three consecutive pots. To shows the empty pot, the “*ATC MAGAZINE INFORMATION*” screen shows 0 at the tool number files. Also note that a dummy pot does not mean an empty pot.
The magazine has no reserve pot, when the magazine is FIX pot specification.

Okuma Alarm-B 2729 No magazine return pot