Mazak Alarm 386 ATC STOP

Mazak Alarm 386 ATC STOP Description When the [ATC STOP] menu key in the machine menu was pressed (that is, when the menu was displayed in reverse mode), the axis…

Mazak Alarm 312 C/S ERROR (PTCATCHER EXTEND)

Mazak Alarm 312 C/S ERROR (PTCATCHER EXTEND) Description The cycle start button has been pressed with the parts catcher (workpiece unloader) extended. Check and remedy Retract (restore) the parts catcher…

Mazak Alarm 218 CHUCKING TYPE NOT SELECTED

Mazak Alarm 218 CHUCKING TYPE NOT SELECTED Description Type of chucking (inner/outer) of spindle chuck is not selected. Check and remedy Select the type of chucking.

Mazak Alarm 221 TURRET CLAMP SENSOR MALFUNCTION

Mazak Alarm 221 TURRET CLAMP SENSOR MALFUNCTION Description In spite of the fact that the milling head is actually clamped, the clamping confirmation sensor (SQ18) does not turn on. In…

Mazak Alarm 324 DIFF. MODE (ORIGIN RET UNFIN.)

Mazak Alarm 324 DIFF. MODE (ORIGIN RET UNFIN.) Description The automatic operation mode was selected without carrying out the zero-point return operation after the power supply had been turned on….

Mazak Alarm 292 SENSOR MALFUNCTION No. 3

Mazak Alarm 292 SENSOR MALFUNCTION No. 3 Description The correction value has exceeded the limit set in the thermal displacement compensation. Check and remedy Check that the thermal sensor is…

Mazak Alarm 293 SENSOR MALFUNCTION No. 4

Mazak Alarm 293 SENSOR MALFUNCTION No. 4 Description The correction value has changed largely than the previous one in the thermal displacement compensation. Check and remedy Check that the thermal…

Mazak Alarm 297 CHUCK PRESSURE DOWN

Mazak Alarm 297 CHUCK PRESSURE DOWN Description The spindle chuck pressure remains reduced in a machine having a spindle chuck pressure guarantee option. Check and remedy Check the spindle chuck…

Mazak Alarm 300 START COND. ERR. (DOOR OPEN)

Mazak Alarm 300 START COND. ERR. (DOOR OPEN) Description The cycle start button was pressed while the front cover (front door) was opened. Check and remedy Close the front cover.

Mazak Alarm 243 MEASURING CONTROLLER MALF.

Mazak Alarm 243 MEASURING CONTROLLER MALF. Description An error occurred at the workpiece measurement controller (option). Check and remedy Check the cause of error at the workpiece measurement controller.

Mazak Alarm 301 START COND. ERR. (TUR UNCLAMP)

Mazak Alarm 301 START COND. ERR. (TUR UNCLAMP) Description The cycle start button was pressed while the milling head was unclamped. Check and remedy Clamp the milling head.

Mazak Alarm 378 HIGH PRESSURE PUMP THERMAL TRIP

Mazak Alarm 378 HIGH PRESSURE PUMP THERMAL TRIP Description The thermal relays in the coolant unit of a machine of the high-pressure coolant specifications have become tripped. Check and remedy…

Mazak Alarm 245 BAR-FEEDER CONTROLLER MALF.

Mazak Alarm 245 BAR-FEEDER CONTROLLER MALF. Description An error occurred at the bar feeder controller. Check and remedy Check the cause of error at the bar feeder controller.

Mazak Alarm 379 TANK PRESSURE LOW

Mazak Alarm 379 TANK PRESSURE LOW Description The pressure in the coolant unit tank of a machine of the high-pressure coolant specifications has decreased. Check and remedy Check and adjust…

Mazak Alarm 248 EXTERNAL CONTROLLER (No.1) MALF.

Mazak Alarm 248 EXTERNAL CONTROLLER (No.1) MALF. Description Failure of controller of a peripheral unit (option) Check and remedy Check the cause of error at the controller of a peripheral…

Mazak Alarm 382 COOLANT SYSTEM MALF.

Mazak Alarm 382 COOLANT SYSTEM MALF. Description An error signal has been sent from the coolant unit of a machine of the highpressure coolant specifications. Check and remedy Check the…

Mazak Alarm 257 ILLEGAL M-CODE

Mazak Alarm 257 ILLEGAL M-CODE Description An illegal M code has been specified. Check and remedy Correct the program.

Mazak Alarm 383 ATC ALM: CARRIER&SHIFT. POS. MALF.

Mazak Alarm 383 ATC ALM: CARRIER&SHIFT. POS. MALF. Description In a machine of the 80/120-tool magazine specifications, the cycle start command or the tool change command was issued when the…

Mazak Alarm 385 START COND. ERR. (Z-AXIS POS.)

Mazak Alarm 385 START COND. ERR. (Z-AXIS POS.) Description Under 20- or 40-tool magazine specifications, executing the machine menu function for opening the ATC cover has been attempted with the…

Mazak Alarm 311 C/S ERROR (TAIL STOCK QUILL)

Mazak Alarm 311 C/S ERROR (TAIL STOCK QUILL) Description The cycle start button has been pressed with the tail spindle not placed at its zero point or advance end. Check…

Mazak Alarm 213 ILLEGAL DESIGNATED TOOL No.

Mazak Alarm 213 ILLEGAL DESIGNATED TOOL No. Description T code that does not exist in the specification is assigned. Check and remedy Correct the program.

Mazak Alarm 275 ROBOT SERVICE EXCEED TIME

Mazak Alarm 275 ROBOT SERVICE EXCEED TIME Description For machines with an optional robot, although a robot service command is given, the confirmation signal does not turn on within a…

Mazak Alarm 236 PARTS-CATCHER SENSOR MALF.

Mazak Alarm 236 PARTS-CATCHER SENSOR MALF. Description For the machine with an optional automatic parts catcher, the advance end confirmation sensor or retract end confirmation sensor does not turn on,…

Mazak Alarm 377 COOLANT LEVEL LOW

Mazak Alarm 377 COOLANT LEVEL LOW Description The coolant level in the coolant unit of a machine of the high-pressure coolant specifications has decreased. Check and remedy Check the coolant…

Mazak Alarm 261 HEAD LUBRICATION ALARM

Mazak Alarm 261 HEAD LUBRICATION ALARM Description The pressure switch (SP25, SP26, SP27) in the spindle cooling unit has worked. Check and remedy Check the coolant level.

Mazak Alarm 391 LD/ULD/ACHG CONDITION ALARM

Mazak Alarm 391 LD/ULD/ACHG CONDITION ALARM Description During ATC, although returning the tool was attempted, the magazine pocket tool confirmation sensor did not detect that tool probably because of dropping….

Mazak Alarm 270 SPINDLE ORIENT EXCEED TIME

Mazak Alarm 270 SPINDLE ORIENT EXCEED TIME Description Although a spindle orientation command is given, the orientation confirmation signal does not turn on within a predetermined time. Check and remedy…

Mazak Alarm 392 MAGAZINE MANUAL INTERR.

Mazak Alarm 392 MAGAZINE MANUAL INTERR. Description Under 20- or 40-tool magazine specifications, the tool change command has been entered or the cycle start button pressed with the magazine manual…

Mazak Alarm 272 TURRET INDEX EXCEED TIME

Mazak Alarm 272 TURRET INDEX EXCEED TIME Description Although a milling head indexing command is given, the index confirmation signal does not turn on within a predetermined time. Check and…

Mazak Alarm 394 ATC CONTROLLER MALF.

Mazak Alarm 394 ATC CONTROLLER MALF. Description An alarm signal has been received from the ATC amplifier. Check and remedy After turning NC power off, turn off the main circuit…

Mazak Alarm 397 MAGAZINE DOOR INTERLOCK

Mazak Alarm 397 MAGAZINE DOOR INTERLOCK Description The magazine door has been opened during issuance of the tool change command or the magazine rotation command. Check and remedy Close the…

Mazak Alarm 224 CHUCK SENSOR MALFUNCTION

Mazak Alarm 224 CHUCK SENSOR MALFUNCTION Description The chuck open or close confirmation sensor fails in function, or both of the sensors are ON simultaneously. Check and remedy The chuck…

Mazak Alarm 325 TL. EYE EXT. IMP.

Mazak Alarm 325 TL. EYE EXT. IMP. Description A TOOL EYE extend/retract command has been given with the SET UP switch remaining set to “O” and the front door remaining…

Mazak Alarm 225 FRONT DOOR SENSOR MALFUNCTION

Mazak Alarm 225 FRONT DOOR SENSOR MALFUNCTION Description For the machine with an optional automatic door, the front door open or close confirmation sensor fails in function, or both of…

Mazak Alarm 341 CONDITION No.2 MISSING

Mazak Alarm 341 CONDITION No.2 MISSING Description The M-code command for milling spindle through air blowout has been issued during coolant injection. Check and remedy Correct the program.