Yasnac Alarms

Yasnac Alarm Error Codes

Yasnac Alarm 280 MACHINE UNREADY

Yasnac Alarm 280 MACHINE UNREADY MX1, MX2, MX3 Alarm 280 MACH UNREADY Yasnac Alarm Description Machine not ready./ Mach rdy off. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 276 P-SET ERROR (S)

Yasnac Alarm 276 P-SET ERROR (S) Yasnac Alarm Description Program set error S. Spindle p-set error at solid tapping. Applies to Yasnac CNC Controls J50

Yasnac Alarm 274 P-SET ERROR (4)

Yasnac Alarm 274 P-SET ERROR (4) Yasnac Alarm Description P set error 4. (if this error occurs in block where G00 is changing to G01, machine stops after completion of…

Yasnac Alarm 273 P-SET ERROR (Z)

Yasnac Alarm 273 P-SET ERROR (Z) Yasnac Alarm Description P set error Z. (if this error occurs in block where G00 is changing to G01, machine stops after completion of…

Yasnac Alarm 272 P-SET ERROR (Y)

Yasnac Alarm 272 P-SET ERROR (Y) Yasnac Alarm Description P set error Y. (if this error occurs in block where G00 is changing to G01, machine stops after completion of…

Yasnac Alarm 271 P-SET ERROR (X)

Yasnac Alarm 271 P-SET ERROR (X) Yasnac Alarm Description P set error X. (if this error occurs in block where G00 is changing to G01, machine stops after completion of…

Yasnac Alarm 264 ZR ERROR PRM (4)

Yasnac Alarm 264 ZR ERROR PRM (4) Yasnac Alarm Description Retraction by reference point return (ER pulse at C phase latch > #6307)./ Retraction by home position (ER pulse at C phase…

Yasnac Alarm 263 ZR ERROR PRM (Z)

Yasnac Alarm 263 ZR ERROR PRM (Z) Yasnac Alarm Description Retraction by reference point return (ER pulse at C phase latch > #6306)./ Retraction by home position (ER pulse at C phase…

Yasnac Alarm 262 ZR ERROR PRM (Y)

Yasnac Alarm 262 ZR ERROR PRM (Y) Yasnac Alarm Description Retraction by reference point return (ER pulse at C phase latch > #6305)./ Retraction by home position (ER pulse at C phase…

Yasnac Alarm 261 ZR ERROR PRM (X)

Yasnac Alarm 261 ZR ERROR PRM (X) Yasnac Alarm Description Retraction by reference point return (ER pulse at C phase latch > #6304)./ Retraction by home position (ER pulse at C phase…

Yasnac Alarm 258 ZR DECLS ERROR (4)

Yasnac Alarm 258 ZR DECLS ERROR (4) Yasnac Alarm Description Ls error (4) deceleration (decls of 4-axis starts chattering on the dog). Applies to Yasnac CNC Controls J50, MX3

Yasnac Alarm 257 ZR DECLS ERROR (Z)

Yasnac Alarm 257 ZR DECLS ERROR (Z) Yasnac Alarm Description Ls error (Z) deceleration (decls of Z-axis starts chattering on the dog). Applies to Yasnac CNC Controls J50, MX3

Yasnac Alarm 256 ZR DECLS ERROR (Y)

Yasnac Alarm 256 ZR DECLS ERROR (Y) Yasnac Alarm Description Ls error (Y) deceleration (decls of Y-axis starts chattering on the dog). Applies to Yasnac CNC Controls J50, MX3

Yasnac Alarm 255 ZR DECLS ERROR (X)

Yasnac Alarm 255 ZR DECLS ERROR (X) Yasnac Alarm Description Ls error (X) deceleration (decls of X-axis starts chattering on the dog). Applies to Yasnac CNC Controls J50, MX3

Yasnac Alarm 253 S-OT3-5 (Z)

Yasnac Alarm 253 S-OT3-5 (Z) Yasnac Alarm Description Stored stroke limit 3rd, 4th, 5th area outside prohibited Z. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 252 S-OT3-5 (Y)

Yasnac Alarm 252 S-OT3-5 (Y) Yasnac Alarm Description Stored stroke limit 3rd, 4th, 5th area outside prohibited Y. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 251 S-OT3-5 (X)

Yasnac Alarm 251 S-OT3-5 (X) Yasnac Alarm Description Stored stroke limit 3rd, 4th, 5th area outside prohibited X. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 250 S-OT3-5 (INSIDE)

Yasnac Alarm 250 S-OT3-5 (INSIDE) Yasnac Alarm Description Stored stroke limit 3rd, 4th, 5th area inside prohibited. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 244 ZR ERROR-POS (4)

Yasnac Alarm 244 ZR ERROR-POS (4) Yasnac Alarm Description Reference point return area error 4. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 243 ZR ERROR-POS (Z)

Yasnac Alarm 243 ZR ERROR-POS (Z) Yasnac Alarm Description Reference point return area error Z. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 242 ZR ERROR-POS (Y)

Yasnac Alarm 242 ZR ERROR-POS (Y) Yasnac Alarm Description Reference point return area error Y. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 241 ZR ERROR-POS (X)

Yasnac Alarm 241 ZR ERROR-POS (X) Yasnac Alarm Description Reference point return area error X. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 234 ZR ERROR-AREA (4)

Yasnac Alarm 234 ZR ERROR-AREA (4) Yasnac Alarm Description Reference point return area error 4. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 233 ZR ERROR-AREA (Z)

Yasnac Alarm 233 ZR ERROR-AREA (Z) Yasnac Alarm Description Reference point return area error Z. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 232 ZR ERROR-AREA (Y)

Yasnac Alarm 232 ZR ERROR-AREA (Y) Yasnac Alarm Description Reference point return area error Y. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 231 ZR ERROR-AREA (X)

Yasnac Alarm 231 ZR ERROR-AREA (X) Yasnac Alarm Description Reference point return area error X. Theoretical C phase type latch unfinished. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 230 TOOL BROKEN

Yasnac Alarm 230 TOOL BROKEN Yasnac Alarm Description At broken tool detection by G32, G33, Z-axis moves to the set position but sens (T) input not turned on. (special specifications)…

Yasnac Alarm 224 S-OT2 (4)

Yasnac Alarm 224 S-OT2 (4) Yasnac Alarm Description Stored stroke limit second area (outside inhibit) 4. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 223 S-OT2 (Z)

Yasnac Alarm 223 S-OT2 (Z) Yasnac Alarm Description Stored stroke limit second area (outside inhibit) Z. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 222 S-OT2 (Y)

Yasnac Alarm 222 S-OT2 (Y) Yasnac Alarm Description Stored stroke limit second area (outside inhibit) Y. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 221 S-OT2 (X)

Yasnac Alarm 221 S-OT2 (X) Yasnac Alarm Description Stored stroke limit second area (outside inhibit) X. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 220 S-OT2 (INSIDE)

Yasnac Alarm 220 S-OT2 (INSIDE) Yasnac Alarm Description Stored stroke limit second area (inside inhibit). Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 214 S-OT1 (4)

Yasnac Alarm 214 S-OT1 (4) Yasnac Alarm Description Stored stroke limit first area 4. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 213 S-OT1 (Z)

Yasnac Alarm 213 S-OT1 (Z) Yasnac Alarm Description Stored stroke limit first area Z. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3

Yasnac Alarm 212 S-OT1 (Y)

Yasnac Alarm 212 S-OT1 (Y) Yasnac Alarm Description Stored stroke limit first area Y. Applies to Yasnac CNC Controls J50, MX1, MX2, MX3