Sinumerik Alarm 16715 Channel %1 block %2 axis %3 spindle not in standstill


Sinumerik Alarm 16715 Channel %1 block %2 axis %3 spindle not in standstill

Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle number

Definitions:
In the applied function (G74, reference point approach), the spindle must be stationary.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.

Remedy:
Program M5 or SPOS/SPOSA in front of the defective block in the part program.

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 16715 Channel %1 block %2 axis %3 spindle not in standstill