Fanuc Alarms

Fanuc Alarms and Errors e.g. Program errors (P/S alarm), Over travel alarms, Servo alarms etc.

Fanuc Alarm 4148 REG NO. NOT COMMAND

Fanuc Alarm 4148 REG NO. NOT COMMAND Fanuc laser alarm Description With the YAG laser, an output command is specified with no execution register number specified.

Fanuc Alarm 4130 STEP TIME NOT SET

Fanuc Alarm 4130 STEP TIME NOT SET Fanuc laser alarm Description The step time is not set for high–speed piercing.

Fanuc Alarm 4131 INCORRECT STEP DISTANCE SETTING

Fanuc Alarm 4131 INCORRECT STEP DISTANCE SETTING Fanuc laser alarm Description In step control, the remaining travel distance becomes shorter than the ramp–down distance before a travel over the ramp–up…

Fanuc Alarm 4132 PARAMETER WAS CHANGED

Fanuc Alarm 4132 PARAMETER WAS CHANGED Fanuc laser alarm Description Parameters No.15223, No. 15242, and No. 15243 have been changed.

Fanuc Alarm 4143 OVER CURRENT ERROR

Fanuc Alarm 4143 OVER CURRENT ERROR Fanuc laser alarm Description With the YAG laser, the current data sent to the oscillator has exceeded the allowable level.

Fanuc Alarm 4144 DATA SENDING ERROR

Fanuc Alarm 4144 DATA SENDING ERROR Fanuc laser alarm Description The READY and SEND signals are out of sync with each other between the CNC and laser controller, so that…

Fanuc Alarm 4145 TOUCH DISPLAY

Fanuc Alarm 4145 TOUCH DISPLAY Fanuc laser alarm Description See the touch display of the oscillator for the YAG laser.

Fanuc Alarm 4146 POWER OVER ERROR

Fanuc Alarm 4146 POWER OVER ERROR Fanuc laser alarm Description With the YAG laser, the power calculated from the data sent to the oscillator has exceeded the allowable level.

Fanuc Alarm 4114 TURBO OVER CURRENT 2

Fanuc Alarm 4114 TURBO OVER CURRENT 2 Fanuc laser alarm Description An overcurrent alarm is issued from turbo–blower 2.

Fanuc Alarm 4141 INITIAL LOADING

Fanuc Alarm 4141 INITIAL LOADING Fanuc laser alarm Description With the YAG laser, an error has occurred during initial loading of laser machining data into the oscillator.

Fanuc Alarm 4142 DATA RECEIVING ERROR

Fanuc Alarm 4142 DATA RECEIVING ERROR Fanuc laser alarm Description A data resend request from the laser controller is kept for more than 10 seconds.

Fanuc Alarm 4112 OUT OF VIBRATION 2

Fanuc Alarm 4112 OUT OF VIBRATION 2 Fanuc laser alarm Description Vibration of turbo–blower 2 is detected.

Fanuc Alarm 4113 T. B NOT STOPPING 2

Fanuc Alarm 4113 T. B NOT STOPPING 2 Fanuc laser alarm Description The speed of turbo–blower 2 has not decreased to the predetermined level within 120 seconds of RUN–OFF.

Fanuc Alarm 4115 TURBO TEMP. 2

Fanuc Alarm 4115 TURBO TEMP. 2 Fanuc laser alarm Description The turbo–blower 2 temperature has exceeded the predetermined level.

Fanuc Alarm 4845 ZONE : ENTERING INHIBITED 8 –Y

Fanuc Alarm 4845 ZONE : ENTERING INHIBITED 8 –Y Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the negative Y direction entered area 8 into…

Fanuc Alarm 4844 ZONE : ENTERING INHIBITED 8 +Y

Fanuc Alarm 4844 ZONE : ENTERING INHIBITED 8 +Y Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the positive Y direction entered area 8 into…

Fanuc Alarm 4843 ZONE : ENTERING INHIBITED 7 –Y

Fanuc Alarm 4843 ZONE : ENTERING INHIBITED 7 –Y Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the negative Y direction entered area 7 into…

Fanuc Alarm 4842 ZONE : ENTERING INHIBITED 7 +Y

Fanuc Alarm 4842 ZONE : ENTERING INHIBITED 7 +Y Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the positive Y direction entered area 7 into…

Fanuc Alarm 4841 ZONE : ENTERING INHIBITED 6 –Y

Fanuc Alarm 4841 ZONE : ENTERING INHIBITED 6 –Y Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the negative Y direction entered area 6 into…

Fanuc Alarm 4840 ZONE : ENTERING INHIBITED 6 +Y

Fanuc Alarm 4840 ZONE : ENTERING INHIBITED 6 +Y Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the positive Y direction entered area 6 into…

Fanuc Alarm 4839 ZONE : ENTERING INHIBITED 5 –Y

Fanuc Alarm 4839 ZONE : ENTERING INHIBITED 5 –Y Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the negative Y direction entered area 5 into…

Fanuc Alarm 4838 ZONE : ENTERING INHIBITED 5 +Y

Fanuc Alarm 4838 ZONE : ENTERING INHIBITED 5 +Y Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the positive Y direction entered area 5 into…

Fanuc Alarm 4825 ZONE : ENTERING INHIBITED 8 –X

Fanuc Alarm 4825 ZONE : ENTERING INHIBITED 8 –X Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the negative X direction entered area 8 into…

Fanuc Alarm 4824 ZONE : ENTERING INHIBITED 8 +X

Fanuc Alarm 4824 ZONE : ENTERING INHIBITED 8 +X Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the positive X direction entered area 8 into…

Fanuc Alarm 4823 ZONE : ENTERING INHIBITED 7 –X

Fanuc Alarm 4823 ZONE : ENTERING INHIBITED 7 –X Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the negative X direction entered area 7 into…

Fanuc Alarm 4822 ZONE : ENTERING INHIBITED 7 +X

Fanuc Alarm 4822 ZONE : ENTERING INHIBITED 7 +X Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the positive X direction entered area 7 into…

Fanuc Alarm 4821 ZONE : ENTERING INHIBITED 6

Fanuc Alarm 4821 ZONE : ENTERING INHIBITED 6 Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the negative X direction entered area 6 into which…

Fanuc Alarm 4820 ZONE : ENTERING INHIBITED 6 +X

Fanuc Alarm 4820 ZONE : ENTERING INHIBITED 6 +X Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the positive X direction entered area 6 into…

Fanuc Alarm 4819 ZONE : ENTERING INHIBITED 5

Fanuc Alarm 4819 ZONE : ENTERING INHIBITED 5 Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the negative X direction entered area 5 into which…

Fanuc Alarm 4818 ZONE : ENTERING INHIBITED 5 +X

Fanuc Alarm 4818 ZONE : ENTERING INHIBITED 5 +X Fanuc Safety zone alarm Description When a safety zone check was executed, the machine moving in the positive X direction entered area 5 into…

Fanuc Alarm 4807 ZONE : PUNCHING INHIBITED 8

Fanuc Alarm 4807 ZONE : PUNCHING INHIBITED 8 Fanuc Safety zone alarm Description When a safety zone check was executed, a punch command was specified in area 8 where punching is inhibited.

Fanuc Alarm 4806 ZONE : PUNCHING INHIBITED 7

Fanuc Alarm 4806 ZONE : PUNCHING INHIBITED 7 Fanuc Safety zone alarm Description When a safety zone check was executed, a punch command was specified in area 7 where punching is inhibited.

Fanuc Alarm 4805 ZONE : PUNCHING INHIBITED 6

Fanuc Alarm 4805 ZONE : PUNCHING INHIBITED 6 Fanuc Safety zone alarm Description When a safety zone check was executed, a punch command was specified in area 6 where punching is inhibited.

Fanuc Alarm 4804 ZONE : PUNCHING INHIBITED 5

Fanuc Alarm 4804 ZONE : PUNCHING INHIBITED 5 Fanuc Safety zone alarm Description When a safety zone check was executed, a punch command was specified in area 5 where punching is inhibited.

Fanuc Alarm 924 SERVO MODULE SETTING ERROR

Fanuc Alarm 924 SERVO MODULE SETTING ERROR Fanuc System alarm Description The digital servo module is not installed. Check that the servo control module or servo interface module on the main…