Centroid Alarms

Centroid Alarms, Errors Messages

Centroid Alarm 314 Waiting for system #NN

Centroid Alarm 314 Waiting for system #NN Cause & Effect M100 or M101 executing. Program will continue once specified PLC system variable changes to the correct state. Action Enter required…

Centroid Alarm 313 Waiting for dwell time

Centroid Alarm 313 Waiting for dwell time Cause & Effect G4 executing. Program waits for specified dwell time then continues.

Centroid Alarm 312 Waiting for PLC operation (Mnn)

Centroid Alarm 312 Waiting for PLC operation (Mnn) Cause & Effect PLC program not clearing PLC operation in progress

Centroid Alarm 311 Waiting for memory #NN

Centroid Alarm 311 Waiting for memory #NN Cause & Effect M100 or M101 executing. Program will continue once specified memory bit changes to the correct state.

Centroid Alarm 310 Waiting for output #NN

Centroid Alarm 310 Waiting for output #NN Cause & Effect M100 or M101 executing. Program will continue once specified output opens or closes.

Centroid Alarm 309 Waiting for CYCLE START button

Centroid Alarm 309 Waiting for CYCLE START button Cause & Effect M0, M1, M100/75, or Block Mode is executed. Action Press Cycle Start

Centroid Alarm 308 Waiting for input #NN

Centroid Alarm 308 Waiting for input #NN Cause & Effect M100 or M101 executing. Program will continue once specified input opens or closes.

Centroid Alarm 307 Operator abort: job canceled

Centroid Alarm 307 Operator abort: job canceled Cause & Effect ESC or CYCLE CANCEL pressed. Job is cancelled.

Centroid Alarm 306 Job finished

Centroid Alarm 306 Job finished Cause & Effect Normal end of CNC program

Centroid Alarm 305 Processing…

Centroid Alarm 305 Processing… Cause & Effect CNC software running in a mode other than MDI

Centroid Alarm 304 MDI…

Centroid Alarm 304 MDI… Cause & Effect CNC software running in MDI mode

Centroid Alarm 303 Paused…

Centroid Alarm 303 Paused… Cause & Effect Motion is paused while a CNC program is running (FEED HOLD)

Centroid Alarm 302 Moving…

Centroid Alarm 302 Moving… Cause & Effect Motors are moving while a CNC program is running.

Centroid Alarm 301 Stopped

Centroid Alarm 301 Stopped Cause & Effect No operations in progress.

Centroid Alarm 222 Autotune run

Centroid Alarm 222 Autotune run Cause & Effect added to log whenever autotune is run.

Centroid Alarm 204 Exiting CNC…Normal Exit

Centroid Alarm 204 Exiting CNC…Normal Exit Cause & Effect CNC control software is shuting down normally.

Centroid Alarm 202 Exiting CNC due to a math error

Centroid Alarm 202 Exiting CNC due to a math error Cause & Effect A floating-point math error occurred. Possible corruption of cnc.tem, cncm.job, or cncm.wcs. Action Contact dealer Delete corrupted…

Centroid Alarm 201 Exiting CNC due to a known error

Centroid Alarm 201 Exiting CNC due to a known error Cause & Effect MPU11 not responding, or mpu11.hex, mpu.plc is missing or damaged. Action Contact dealer Check for possible software…

Centroid Alarm 199 CNC started

Centroid Alarm 199 CNC started Cause & Effect CNC control software has started.

Centroid Alarm 106 The PC clock appears to be wrong.

Centroid Alarm 106 The PC clock appears to be wrong. Cause & Effect The time on the PC internal clock is earlier than the time recorded in a previously stored…

Centroid Alarm 105 mpu.plc file read error..cannot continue

Centroid Alarm 105 mpu.plc file read error..cannot continue Cause & Effect Missing or error in mpu.plc. Action Contact dealer Install or recompile PLC program.

Centroid Alarm 104 Error sending PID setup

Centroid Alarm 104 Error sending PID setup Cause & Effect Unable to send PID setup command to MPU11.Cannot communicate with MPU11 or it is not plugged in. Action Inspect MPU11…

Centroid Alarm 103 Error sending setup

Centroid Alarm 103 Error sending setup Cause & Effect Unable to send setup command to MPU11.Cannot communicate with MPU11 or it is not plugged in. Action Inspect MPU11 connection,or fix…

Centroid Alarm 102 Error initializing CPU…cannot continue.

Centroid Alarm 102 Error initializing CPU…cannot continue. Alarm Cause & Effect: Error while sending .hex file. Cannot communicate with MPU11 or it is not plugged in Alarm Action: Inspect MPU11 connection,or…