Sinumerik Alarm 26012 Axis %1 QEC: feed forward control not active


Sinumerik Alarm 26012 Axis %1 QEC: feed forward control not active

Parameters:
%1 = Axis name, spindle number

Definitions:
The error criterion for determining the quadrant error necessitates a correctly set feed forward control. The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

Reactions:
– Mode group not ready.
– Channel not ready.
– Channel not ready.
– NC Start disable in this channel.
– Alarm display.

Remedy:
Switch on feed forward control and set it correctly.

Program Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 26012 Axis %1 QEC: feed forward control not active