Sinumerik Alarms

Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D

Sinumerik Alarm 112211 Tool preselection could not be processed. Insufficient NC memory.

Sinumerik Alarm 112211 Tool preselection could not be processed. Insufficient NC memory. Definitions: When tool preselection is processed, the NC program has to be generated again. Hereby the old NC…

Sinumerik Alarm 112502 Insufficient memory, abort in line %1

Sinumerik Alarm 112502 Insufficient memory, abort in line %1 Parameters: %1 = Line number Definitions: The program cannot interpret a program block with contour programming. Contour not in the directory….

Sinumerik Alarm 112300 Tool management type 2 not possible. Magazine not completely loaded.

Sinumerik Alarm 112300 Tool management type 2 not possible. Magazine not completely loaded. Definitions: The magazine is not completely loaded with tools. In the magazine of tool management type 2,…

Sinumerik Alarm 112301 Tool management type 2 not possible. The magazine is not sorted as in the tool list.

Sinumerik Alarm 112301 Tool management type 2 not possible. The magazine is not sorted as in the tool list. Definitions: The magazine list sorting does not correspond to that of…

Sinumerik Alarm 112323 Replace swivel head.

Sinumerik Alarm 112323 Replace swivel head. Definitions: The operator is prompted to remove the specified swivel head from the spindle. Reactions: – Alarm display. Remedy: Replace swivel head. When doing…

Sinumerik Alarm 112324 Load swivel head.

Sinumerik Alarm 112324 Load swivel head. Definitions: The operator is prompted to load the specified swivel head into the spindle. Reactions: – Alarm display. Remedy: Load swivel head. When doing…

Sinumerik Alarm 112325 Exchange swivel head.

Sinumerik Alarm 112325 Exchange swivel head. Definitions: The operator is prompted to replace the specified swivel head in the spindle with the new swivel head. Reactions: – Alarm display. Remedy:…

Sinumerik Alarm 112326 Set swivel head

Sinumerik Alarm 112326 Set swivel head Definitions: The operator is prompted to set the swivel head in accordance with the specified data. Reactions: – Alarm display. Remedy: Set swivel head….

Sinumerik Alarm 112327 Angle not in permissible area

Sinumerik Alarm 112327 Angle not in permissible area Definitions: The programmed machining cannot be carried out with the swivel head. Reactions: – Alarm display. Remedy: If necessary, clamp the workpiece…

Sinumerik Alarm 120000 Area %1 cannot be loaded! Acknowledge alarm, press area switchover key!

Sinumerik Alarm 120000 Area %1 cannot be loaded! Acknowledge alarm, press area switchover key! Parameters: %1 = Operating area name Definitions: One of the applications listed in the REGIE.INI could…

Sinumerik Alarm 112999 Faulty grafic data. Exit graphic and restart

Sinumerik Alarm 112999 Faulty grafic data. Exit graphic and restart Definitions: More data was generated than can be read from the operator panel. Stop the graphic. Reactions: – Alarm display….

Sinumerik Alarm 120309 The selection is not possible. Please close the simulation and repeat the selection.

Sinumerik Alarm 120309 The selection is not possible. Please close the simulation and repeat the selection. Definitions: The simulation is currently active in the program area. A simultaneous editing is…

Sinumerik Alarm 120006 The channel switchover is currently disabled by area %1.

Sinumerik Alarm 120006 The channel switchover is currently disabled by area %1. Parameters: %1 = Operating area name Definitions: The area %1 has disabled the channel switchover at the moment,…

Sinumerik Alarm 120007 The channel switchover is currently disabled.

Sinumerik Alarm 120007 The channel switchover is currently disabled. Definitions: The channel switchover is currently disabled, as a critical operation, during which no channel switchover may occur, is being carried…

Sinumerik Alarm 300000 Hardware drive bus: DCM not present

Sinumerik Alarm 300000 Hardware drive bus: DCM not present Definitions: The DCM (Drive Communication Master, an ASIC on the NCU module that takes control of the drive bus) has not…

Sinumerik Alarm 120008 Control unit switchover, PLC timeout: 001 control unit switchover, PLC timeout: 002 control unit switchover, PLC timeout: 003

Sinumerik Alarm 120008 Control unit switchover, PLC timeout: 001 control unit switchover, PLC timeout: 002 control unit switchover, PLC timeout: 003 Definitions: • 001: MMC would like to go offline…

Sinumerik Alarm 112504 File faulty or not available: %1 Parameters: %1 = File name

Sinumerik Alarm 112504 File faulty or not available: %1 Parameters: %1 = File name Definitions: The program cannot interpret a program block with contour programming. Contour not in the directory….

Sinumerik Alarm 300002 Axis %1 drive number %2 assigned twice

Sinumerik Alarm 300002 Axis %1 drive number %2 assigned twice Parameters: %1 = NC axis number %2 = Drive number Definitions: The drive logic number in the NCK MD 13010…

Sinumerik Alarm 112505 Error when interpreting the contour %1

Sinumerik Alarm 112505 Error when interpreting the contour %1 Parameters: %1 = Contour name Definitions: Contour is faulty. Reactions: – NC Start disable in this channel. – Alarm display. Remedy:…

Sinumerik Alarm 300003 Axis %1 drive %2 wrong module type %3

Sinumerik Alarm 300003 Axis %1 drive %2 wrong module type %3 Parameters: %1 = NC axis number %2 = Drive number %3 = Incorrect module type Definitions: The hardware configuration…

Sinumerik Alarm 112506 Maximum number of contour elements exceeded %1

Sinumerik Alarm 112506 Maximum number of contour elements exceeded %1 Definitions: The maximum permissible number of 50 contour elements was exceeded when interpreting the machining sequence of a contour. Reactions:…

Sinumerik Alarm 120201 Communication failure

Sinumerik Alarm 120201 Communication failure Definitions: The operator panel is connected with the NC and PLC via a serial bus. This alarm occurs when the communication to these components is…

Sinumerik Alarm 112541 Program cannot be interpreted

Sinumerik Alarm 112541 Program cannot be interpreted Definitions: The program cannot be interpreted as a ShopMill program during loading, as the program header is missing. Reactions: – NC Start disable…

Sinumerik Alarm 112604 Connection to the PLC broken off

Sinumerik Alarm 112604 Connection to the PLC broken off Definitions: Acknowledgement to the PLC user program, that the connection with the PCU has been broken off. ShopMill PLC is terminated….

Sinumerik Alarm 112605 Asynchronous subroutine was not executed

Sinumerik Alarm 112605 Asynchronous subroutine was not executed Definitions: The input values could not be correctly processed by the NC. Reactions: – Alarm display. Remedy: Perform an NCK reset Program…

Sinumerik Alarm 112650 Unknown PLC error

Sinumerik Alarm 112650 Unknown PLC error Definitions: The PLC has announced an error that is unknown in the operator panel. Reactions: – NC Start disable in this channel. – Alarm…

Sinumerik Alarm 120002 Area %1 is still active. Please deactivate area %1

Sinumerik Alarm 120002 Area %1 is still active. Please deactivate area %1 Parameters: %1 = Operating area name Definitions: When the MMC system is closed (closing the master control), an…

Sinumerik Alarm 120005 Please acknowledge the dialog box in area %1

Sinumerik Alarm 120005 Please acknowledge the dialog box in area %1 Parameters: %1 = Operating area name Definitions: The area %1 could not be deselected, as in this area a…

Sinumerik Alarm 120310 The selection is not possible. Please wait for the pending action or terminate it, then repeat the selection.

Sinumerik Alarm 120310 The selection is not possible. Please wait for the pending action or terminate it, then repeat the selection. Definitions: In the program area, programs are currently being…

Sinumerik Alarm 120200 Image preparation suppressed

Sinumerik Alarm 120200 Image preparation suppressed Definitions: The control is so heavily loaded by the processing of a subroutine, that it cannot keep all the display values up-to-date. Reactions: –…

Sinumerik Alarm 120202 Waiting for a connection to the NC

Sinumerik Alarm 120202 Waiting for a connection to the NC Definitions: The operator panel is connected with the NC and PLC via a serial bus. This alarm occurs if the…

Sinumerik Alarm 120301 Faulty entry for hardkey ‘Program’ in Keys.ini.

Sinumerik Alarm 120301 Faulty entry for hardkey ‘Program’ in Keys.ini. Definitions: The configuration in Keys.ini is wrong. Reactions: – Alarm display. Remedy: In Keys.ini, the parameter ChildTask:=26 has to be…

Sinumerik Alarm 120302 The selection is not possible. A program has to have been edited first via the area ‘Program’.

Sinumerik Alarm 120302 The selection is not possible. A program has to have been edited first via the area ‘Program’. Definitions: A program can only be selected via the hardkey…

Sinumerik Alarm 120303 The selection is not possible. The edited file %1 no longer exists.

Sinumerik Alarm 120303 The selection is not possible. The edited file %1 no longer exists. Parameters: %1 = Program name with path Definitions: The file edited last in the program…

Sinumerik Alarm 120304 The selection is not possible. The file %1 has insufficient read rights.

Sinumerik Alarm 120304 The selection is not possible. The file %1 has insufficient read rights. Parameters: %1 = Program name with path Definitions: The file has insufficient read rights for…