Sinumerik Alarms

Siemens Sinumerik Alarms Errors SINUMERIK 840D/840Di/810D

Sinumerik Alarm 105041 Block number is too large!

Sinumerik Alarm 105041 Block number is too large! Definitions: The set increment and the size of the program cause the block number to be greater than 999999. Reactions: – –…

Sinumerik Alarm 300735 Axis %1 drive %2 field weakening speed invalid

Sinumerik Alarm 300735 Axis %1 drive %2 field weakening speed invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed…

Sinumerik Alarm 300731 Axis %1 drive %2 rated power less than or equal to zero

Sinumerik Alarm 300731 Axis %1 drive %2 rated power less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD…

Sinumerik Alarm 105042 Impermissible block number!

Sinumerik Alarm 105042 Impermissible block number! Definitions: The first block number is less than 0 or greater than 999999. Reactions: – – Remedy: – Program Continuation: Internal

Sinumerik Alarm 300732 Axis %1 drive %2 rated speed less than or equal to zero

Sinumerik Alarm 300732 Axis %1 drive %2 rated speed less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD…

Sinumerik Alarm 300734 Axis %1 drive %2 zero load current less than or equal to zero

Sinumerik Alarm 300734 Axis %1 drive %2 zero load current less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in…

Sinumerik Alarm 300745 Axis %1 drive %2 limit values for safe end positions exchanged

Sinumerik Alarm 300745 Axis %1 drive %2 limit values for safe end positions exchanged Parameters: %1 = NC axis number %2 = Drive number Definitions: For the safe end position…

Sinumerik Alarm 300733 Axis %1 drive %2 zero load voltage invalid

Sinumerik Alarm 300733 Axis %1 drive %2 zero load voltage invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Error in the no-load voltage (MD 1135): •…

Sinumerik Alarm 300736 Axis %1 drive %2 Lh characteristic invalid

Sinumerik Alarm 300736 Axis %1 drive %2 Lh characteristic invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD 1143: $MD_LH_CURVE_UPPER_SPEED (LH curve upper…

Sinumerik Alarm 300737 Axis %1 drive %2 configuration of two EnDat encoders not possible

Sinumerik Alarm 300737 Axis %1 drive %2 configuration of two EnDat encoders not possible Parameters: %1 = NC axis number %2 = Drive number Definitions: The MCU hardware does not…

Sinumerik Alarm 300738 Axis %1 drive %2 module number for measuring system not possible

Sinumerik Alarm 300738 Axis %1 drive %2 module number for measuring system not possible Parameters: %1 = NC axis number %2 = Drive number Definitions: The NC has assigned the…

Sinumerik Alarm 300739 Axis %1 drive %2 measuring system already used as motor measuring system

Sinumerik Alarm 300739 Axis %1 drive %2 measuring system already used as motor measuring system Parameters: %1 = NC axis number %2 = Drive number Definitions: The NC has assigned…

Sinumerik Alarm 300740 Axis %1 drive %2 measuring system used several times

Sinumerik Alarm 300740 Axis %1 drive %2 measuring system used several times Parameters: %1 = NC axis number %2 = Drive number Definitions: The NC has assigned the direct measuring…

Sinumerik Alarm 300741 Axis %1 drive %2 asynchronous mode: feedforward control gain out of range

Sinumerik Alarm 300741 Axis %1 drive %2 asynchronous mode: feedforward control gain out of range Parameters: %1 = NC axis number %2 = Drive number Definitions: If motor inertia and…

Sinumerik Alarm 300742 Axis %1 drive %2 voltage/frequency mode: converter frequency invalid

Sinumerik Alarm 300742 Axis %1 drive %2 voltage/frequency mode: converter frequency invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Only converter frequencies (MD 1100: $MD_PWM_FREQUENCY (pulse…

Sinumerik Alarm 300743 Axis %1 drive %2 function not supported on this 611D controller module

Sinumerik Alarm 300743 Axis %1 drive %2 function not supported on this 611D controller module Parameters: %1 = NC axis number %2 = Drive number Definitions: The 611D Performance control…

Sinumerik Alarm 300744 Axis %1 drive %2 safety monitoring checksum invalid, confirmation and acceptance test required!

Sinumerik Alarm 300744 Axis %1 drive %2 safety monitoring checksum invalid, confirmation and acceptance test required! Parameters: %1 = NC axis number %2 = Drive number Definitions: The actual checksum…

Sinumerik Alarm 300752 Axis %1 drive %2 blocking frequency of setpoint current filter too high

Sinumerik Alarm 300752 Axis %1 drive %2 blocking frequency of setpoint current filter too high Parameters: %1 = NC axis number %2 = Drive number Definitions: The blocking frequency of…

Sinumerik Alarm 300753 Axis %1 drive %2 rotor position identification current less than minimal value

Sinumerik Alarm 300753 Axis %1 drive %2 rotor position identification current less than minimal value Parameters: %1 = NC axis number %2 = Drive number Definitions: The current set in…

Sinumerik Alarm 300755 Axis %1 drive %2 voltage/frequency mode: motor is turning

Sinumerik Alarm 300755 Axis %1 drive %2 voltage/frequency mode: motor is turning Parameters: %1 = NC axis number %2 = Drive number Definitions: The motor did not come to a…

Sinumerik Alarm 300756 Axis %1 drive %2 speed hysteresis of setpoint current smoothing invalid

Sinumerik Alarm 300756 Axis %1 drive %2 speed hysteresis of setpoint current smoothing invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD 1246:…

Sinumerik Alarm 300760 Axis %1 drive %2 generator mode: emergency retraction speed > max. motor speed

Sinumerik Alarm 300760 Axis %1 drive %2 generator mode: emergency retraction speed > max. motor speed Parameters: %1 = NC axis number %2 = Drive number Definitions: The value entered…

Sinumerik Alarm 300761 Axis %1 drive %2 generator mode: minimum axis speed > max. motor speed

Sinumerik Alarm 300761 Axis %1 drive %2 generator mode: minimum axis speed > max. motor speed Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in…

Sinumerik Alarm 300746 Axis %1 drive %2 SBH/SG not enabled

Sinumerik Alarm 300746 Axis %1 drive %2 SBH/SG not enabled Parameters: %1 = NC axis number %2 = Drive number Definitions: In the machine data 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable)…

Sinumerik Alarm 300762 Axis %1 drive %2 emergency retraction mode/generator mode already active

Sinumerik Alarm 300762 Axis %1 drive %2 emergency retraction mode/generator mode already active Parameters: %1 = NC axis number %2 = Drive number Definitions: Emergency retraction or generator mode already…

Sinumerik Alarm 300749 Axis %1 drive %2 conversion factor between motor and load too large

Sinumerik Alarm 300749 Axis %1 drive %2 conversion factor between motor and load too large Parameters: %1 = NC axis number %2 = Drive number Definitions: The conversion factor from…

Sinumerik Alarm 300750 Axis %1 drive %2 parameterization error in speed control adaption

Sinumerik Alarm 300750 Axis %1 drive %2 parameterization error in speed control adaption Parameters: %1 = NC axis number %2 = Drive number Definitions: The upper adaptation speed MD 1412:…

Sinumerik Alarm 300782 Axis %1 drive %2 reactance less than or equal to zero

Sinumerik Alarm 300782 Axis %1 drive %2 reactance less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in MD 1139:…

Sinumerik Alarm 300751 Axis %1 drive %2 speed control gain too high

Sinumerik Alarm 300751 Axis %1 drive %2 speed control gain too high Parameters: %1 = NC axis number %2 = Drive number Definitions: The proportional gain of the speed controller…

Sinumerik Alarm 300783 Axis %1 drive %2 rotor resistance invalid

Sinumerik Alarm 300783 Axis %1 drive %2 rotor resistance invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in drive MD 1138: $MD_ROTOR_COLD_RESISTANCE (cold rotor…

Sinumerik Alarm 300784 Axis %1 drive %2 zero load voltage invalid

Sinumerik Alarm 300784 Axis %1 drive %2 zero load voltage invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: Error in the no-load voltage (MD 1135): •…

Sinumerik Alarm 300785 Axis %1 drive %2 zero load current less than or equal to zero

Sinumerik Alarm 300785 Axis %1 drive %2 zero load current less than or equal to zero Parameters: %1 = NC axis number %2 = Drive number Definitions: The value in…

Sinumerik Alarm 300754 Axis %1 drive %2 signal number of var. signaling function invalid

Sinumerik Alarm 300754 Axis %1 drive %2 signal number of var. signaling function invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The signal number for the…

Sinumerik Alarm 300757 Axis %1 drive %2 adaption factor of torque limit invalid

Sinumerik Alarm 300757 Axis %1 drive %2 adaption factor of torque limit invalid Parameters: %1 = NC axis number %2 = Drive number Definitions: The torque adaptation factor MD 1191:…

Sinumerik Alarm 300758 Axis %1 drive %2 generator mode: response voltage > switch-off threshold

Sinumerik Alarm 300758 Axis %1 drive %2 generator mode: response voltage > switch-off threshold Parameters: %1 = NC axis number %2 = Drive number Definitions: The sum of the values…